Skip to main content
Window · Vinyl Frame NFRC LSE · Product Line LSE-M-5 ENERGY STAR Most Efficient Eligible

L.A.S. Enterprises — Weathergard II - Vinyl Double Hung · Double Hung

Positioning #564/1,352 in certified Window, L.A.S. Enterprises Weathergard II - Vinyl Double Hung pairs Vinyl frame construction with 210 glazing options rated between 0.14 and 0.49 SHGC across Northern, North-Central, South-Central, Southern. Across 5 certified L.A.S. Enterprises product families, its thermal resistance spans 0.19 to 0.29 U-Factor and the line includes 45 ENERGY STAR Most Efficient packages (21.4% of line).

Min U-Factor
0.19
SHGC Range
0.14-0.49
Certified Options
210
Category Standing
#564 of 1,352

How does L.A.S. Enterprises Weathergard II - Vinyl Double Hung compare thermally against Window peers?

L.A.S. Enterprises Weathergard II - Vinyl Double Hung achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Weathergard II - Vinyl Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Weathergard II - Vinyl Double Hung (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Weathergard II - Vinyl Double Hung Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), Weathergard II - Vinyl Double Hung reaches 0.19 on its lowest-conductivity package — #429 of 1,009 in Vinyl, tied with 83 others at 0.19, more insulating than 49.3% of Vinyl lines (At median vs Vinyl peers). Pairing NFRC ID LSE across multi-pane fills shifts U-Factor from 0.29 down toward 0.19.

Regional qualification covers Northern, North-Central, South-Central, Southern. 45 configurations meet ENERGY STAR Most Efficient criteria while 113 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 114.0 BTU/hr (-13.6% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-10-03 and cert timestamp 2025-08-28.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 210 certified glazing combinations for Weathergard II - Vinyl Double Hung (NFRC LSE) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 113 packages (38 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 87 packages (35 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 59 packages (12 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 96 packages (12 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does L.A.S. Enterprises produce?

Compare other active L.A.S. Enterprises certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to L.A.S. Enterprises Weathergard II - Vinyl Double Hung appear below.

Where does L.A.S. Enterprises Weathergard II - Vinyl Double Hung stand thermally among ENERGY STAR Window lines?

L.A.S. Enterprises Weathergard II - Vinyl Double Hung spans 210 certified configurations with U-Factors between 0.19 and 0.29 and SHGC values from 0.14 to 0.49. Ranked #564 of 1,352 Window families, it carries 45 Most Efficient options.

Can homeowners install Weathergard II - Vinyl Double Hung in cold Northern ENERGY STAR counties?

L.A.S. Enterprises Weathergard II - Vinyl Double Hung supplies 113 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.29, so inspect the NFRC order sheet before purchase.

How does a 3x5 ft Weathergard II - Vinyl Double Hung window perform under a 40 deg F temperature drop?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 114.0 BTU/hr on Weathergard II - Vinyl Double Hung's lowest-U package (0.19), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.29 transfer proportionally more energy.

What are the practical limitations of specifying Weathergard II - Vinyl Double Hung?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Weathergard II - Vinyl Double Hung options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

How many Weathergard II - Vinyl Double Hung glazing packages pass Southern solar-heat rules?

Warm-climate homeowners have 96 Southern-approved options within Weathergard II - Vinyl Double Hung spanning SHGC down to 0.14. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

What glazing share inside Weathergard II - Vinyl Double Hung qualifies as Most Efficient?

No. Exactly 45 of 210 configurations (21.4%) earn ENERGY STAR Most Efficient status in Weathergard II - Vinyl Double Hung; the remaining standard v7.0 options pass base zone limits only.

What 2026 federal tax credit and Lead RRP rules apply to Weathergard II - Vinyl Double Hung?

Any Weathergard II - Vinyl Double Hung purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do you cross-check NFRC LSE and product line LSE-M-5 on delivery?

Confirm both the paper NFRC label and permanent corner glass etch match line LSE-M-5 and NFRC ID LSE before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for L.A.S. Enterprises Weathergard II - Vinyl Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)