Skip to main content
Window · Vinyl Frame NFRC VDC · Product Line VDC-K-15 ENERGY STAR Most Efficient Eligible

Vinyl Design Corporation — DuraTrust / TrustGard / TrustSeries Sash Horizontal Slider · Double Slider

Vinyl Design Corporation DuraTrust / TrustGard / TrustSeries Sash Horizontal Slider is a Double Slider assembly with a Vinyl frame that reaches a minimum U-Factor of 0.19 across 210 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #564 of 1,352 in Window, its thermal floor is 0.01 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.17 to 0.48.

Min U-Factor
0.19
SHGC Range
0.17-0.48
Certified Options
210
Category Standing
#564 of 1,352

How does Vinyl Design Corporation DuraTrust / TrustGard / TrustSeries Sash Horizontal Slider compare thermally against Window peers?

Vinyl Design Corporation DuraTrust / TrustGard / TrustSeries Sash Horizontal Slider achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. DuraTrust / TrustGard / TrustSeries Sash Horizontal SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing DuraTrust / TrustGard / TrustSeries Sash Horizontal Slider (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

DuraTrust / TrustGard / TrustSeries Sash Horizontal Slider Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), DuraTrust / TrustGard / TrustSeries Sash Horizontal Slider is 0.01 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.19-0.30.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 13 configurations meet ENERGY STAR Most Efficient criteria while 26 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2025-12-08 and FENSTAR license 2018-10-03 inside EPA Version 7.0 tables. Heat transfer computes to 114.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 210 certified glazing combinations for DuraTrust / TrustGard / TrustSeries Sash Horizontal Slider (NFRC VDC) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 26 packages (12 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 68 packages (12 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 123 packages (3 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 160 packages (4 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Vinyl Design Corporation produce?

Compare other active Vinyl Design Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Vinyl Design Corporation DuraTrust / TrustGard / TrustSeries Sash Horizontal Slider appear below.

How well does DuraTrust / TrustGard / TrustSeries Sash Horizontal Slider by Vinyl Design Corporation insulate relative to Window benchmarks?

Built with Vinyl framing in Dual-Slide Horizontal (HSXX) style, Vinyl Design Corporation DuraTrust / TrustGard / TrustSeries Sash Horizontal Slider offers 210 Version 7.0 configurations from U 0.19 up to 0.30, posting -0.01 against the Window median of 0.20 with 13 Most Efficient picks.

Is DuraTrust / TrustGard / TrustSeries Sash Horizontal Slider approved for Northern Zone heating climates?

Yes. 26 packages in Vinyl Design Corporation DuraTrust / TrustGard / TrustSeries Sash Horizontal Slider clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.30.

How do you calculate winter heat conduction for Vinyl Design Corporation DuraTrust / TrustGard / TrustSeries Sash Horizontal Slider?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), DuraTrust / TrustGard / TrustSeries Sash Horizontal Slider at U 0.19 conducts 114.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Who should NOT choose Vinyl Design Corporation DuraTrust / TrustGard / TrustSeries Sash Horizontal Slider for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on DuraTrust / TrustGard / TrustSeries Sash Horizontal Slider options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Does DuraTrust / TrustGard / TrustSeries Sash Horizontal Slider meet Southern hot-climate SHGC caps (<= 0.23)?

Across Northern, North-Central, South-Central, Southern, 160 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Vinyl Design Corporation DuraTrust / TrustGard / TrustSeries Sash Horizontal Slider, while total line SHGC reaches 0.48 in colder packages.

Are all 210 DuraTrust / TrustGard / TrustSeries Sash Horizontal Slider configurations ENERGY STAR Most Efficient?

Within DuraTrust / TrustGard / TrustSeries Sash Horizontal Slider, 6.2% (13 of 210) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

How do the 25C sunset and pre-1978 Lead RRP rules affect DuraTrust / TrustGard / TrustSeries Sash Horizontal Slider?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Vinyl Design Corporation upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

Where are NFRC and IGCC identification marks located on DuraTrust / TrustGard / TrustSeries Sash Horizontal Slider?

Confirm both the paper NFRC label and permanent corner glass etch match line VDC-K-15 and NFRC ID VDC before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Vinyl Design Corporation DuraTrust / TrustGard / TrustSeries Sash Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)