L.A.S. Enterprises — Weathergard II - Vinyl Double Slider · Double Slider
Positioning #564/1,352 in certified Window, L.A.S. Enterprises Weathergard II - Vinyl Double Slider pairs Vinyl frame construction with 210 glazing options rated between 0.14 and 0.49 SHGC across Northern, North-Central, South-Central, Southern. Across 5 certified L.A.S. Enterprises product families, its thermal resistance spans 0.19 to 0.29 U-Factor and the line includes 60 ENERGY STAR Most Efficient packages (28.6% of line).
- Min U-Factor
- 0.19
- SHGC Range
- 0.14-0.49
- Certified Options
- 210
- Category Standing
- #564 of 1,352
How does L.A.S. Enterprises Weathergard II - Vinyl Double Slider compare thermally against Window peers?
L.A.S. Enterprises Weathergard II - Vinyl Double Slider achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places L.A.S. Enterprises Weathergard II - Vinyl Double Slider at rank #564 of 1,352 (tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.14-0.49 band.
Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 60 configurations meet ENERGY STAR Most Efficient criteria while 113 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 114.0 BTU/hr (-13.6% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-10-03 and cert timestamp 2025-08-28.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 210 certified glazing combinations for Weathergard II - Vinyl Double Slider (NFRC LSE) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 113 packages (53 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 87 packages (45 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 84 packages (12 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 96 packages (12 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Vinyl Design Corporation — DuraTrust / TrustGard / TrustSeries Sash Horizontal Slider | Vinyl | 0.19 | 0.17 | 210 |
| WeatherBarr Windows and Doors — TrustGard Direct Set Picture Window | Vinyl | 0.19 | 0.18 | 213 |
| Advanced Window Corp. — 5300 Picture Window | Vinyl | 0.19 | 0.16 | 195 |
| Joyce Manufacturing Co. — Insulator INAW Awning | Vinyl | 0.19 | 0.14 | 242 |
| Joyce Manufacturing Co. — Insulator INCA Casement | Vinyl | 0.19 | 0.14 | 243 |
What other certified series does L.A.S. Enterprises produce?
Compare other active L.A.S. Enterprises certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Weathergard II - Vinyl Double Hung
U-Factor 0.19–0.29 · 210 certified options.
Weathergard II - Vinyl Casement
U-Factor 0.24–0.25 · 44 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to L.A.S. Enterprises Weathergard II - Vinyl Double Slider appear below.
How well does Weathergard II - Vinyl Double Slider by L.A.S. Enterprises insulate relative to Window benchmarks?
Across 210 tested NFRC glazing configurations, L.A.S. Enterprises Weathergard II - Vinyl Double Slider with Vinyl framing and Dual-Slide Horizontal (HSXX) style reaches a 0.19 minimum U-Factor and 0.14-0.49 SHGC band. It places #564 among 1,352 Window series—top 49.6%.
Does L.A.S. Enterprises Weathergard II - Vinyl Double Slider qualify for the ENERGY STAR Northern Zone?
L.A.S. Enterprises Weathergard II - Vinyl Double Slider supplies 113 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.29, so inspect the NFRC order sheet before purchase.
How much winter heat loss does Weathergard II - Vinyl Double Slider conduct across a 15 sq ft opening?
Using NFRC LSE U-Factor 0.19, a 15 sq ft Dual-Slide Horizontal (HSXX) assembly conducts 114.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-18.0 BTU/hr margin).
Who should NOT choose L.A.S. Enterprises Weathergard II - Vinyl Double Slider for a residential project?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Weathergard II - Vinyl Double Slider options exceeding U 0.22. Additionally, do not order Dual-Slide Horizontal (HSXX) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
What Southern ENERGY STAR v7.0 options exist in Weathergard II - Vinyl Double Slider?
Warm-climate homeowners have 96 Southern-approved options within Weathergard II - Vinyl Double Slider spanning SHGC down to 0.14. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
Which package tier in Weathergard II - Vinyl Double Slider holds Most Efficient recognition?
No. Exactly 60 of 210 configurations (28.6%) earn ENERGY STAR Most Efficient status in Weathergard II - Vinyl Double Slider; the remaining standard v7.0 options pass base zone limits only.
Can homeowners claim Form 5695 credits on L.A.S. Enterprises Weathergard II - Vinyl Double Slider in 2026?
Any Weathergard II - Vinyl Double Slider purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
What permanent glass etch marks verify Weathergard II - Vinyl Double Slider after sticker removal?
Inspectors match the temporary NFRC sticker (U 0.19-0.29, SHGC 0.14-0.49) against permit drawings for line LSE-M-4. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for L.A.S. Enterprises Weathergard II - Vinyl Double Slider come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)