Skip to main content
Window · Vinyl Frame NFRC LSE · Product Line LSE-M-11

L.A.S. Enterprises — Weathergard II - Vinyl Single Hung · Single Hung

With a minimum U-Factor of 0.28—+0.08 compared against the 0.20 Window median—L.A.S. Enterprises Weathergard II - Vinyl Single Hung spans 60 tested options across South-Central, Southern up to 0.28 U-Factor. Carrying NFRC CPD code LSE, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.14 and 0.21.

Min U-Factor
0.28
SHGC Range
0.14-0.21
Certified Options
60
Category Standing
#1,320 of 1,352

How does L.A.S. Enterprises Weathergard II - Vinyl Single Hung compare thermally against Window peers?

L.A.S. Enterprises Weathergard II - Vinyl Single Hung achieves a 0.28 thermal floor across Window lines, placing #1,320 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Weathergard II - Vinyl Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.28-0.30 containing Weathergard II - Vinyl Single Hung (U 0.28).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.30This model: U 0.2820.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Weathergard II - Vinyl Single Hung Cohort StandingMin U-Factor 0.28 stands at rank #1,320 of 1,352, outperforming 2.0% of peers.Min U-Factor 0.28Rank #1,320 of 1,352 (2.0% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Weathergard II - Vinyl Single Hung is 0.08 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.28-0.28.

Evaluating climate compliance across South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.14 lowers cooling load.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 168.0 BTU/hr (+27.3% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-10-03 and cert timestamp 2025-08-28.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 60 certified glazing combinations for Weathergard II - Vinyl Single Hung (NFRC LSE) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 60 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 60 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.28 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
All America Windows LLC — 1900 Series Single Hung Vinyl 0.28 0.19 36
Value Windows & Doors — Galaxy Single Slider Vinyl 0.28 0.19 87
ViWinTech Window — 2100 Single Slider Vinyl 0.28 0.18 87
Duke Vinyl Windows — Marquis Double Hung Vinyl 0.28 0.19 12
Duke Vinyl Windows — Marquis Horizontal Slider Vinyl 0.28 0.19 12

What other certified series does L.A.S. Enterprises produce?

Compare other active L.A.S. Enterprises certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to L.A.S. Enterprises Weathergard II - Vinyl Single Hung appear below.

How efficient is L.A.S. Enterprises Weathergard II - Vinyl Single Hung compared with peer Window models?

Across 60 tested NFRC glazing configurations, L.A.S. Enterprises Weathergard II - Vinyl Single Hung with Vinyl framing and Single-Hung (VSSH) style reaches a 0.28 minimum U-Factor and 0.14-0.21 SHGC band. It places #1,320 among 1,352 Window series—more insulating than 0.7%.

Can homeowners install Weathergard II - Vinyl Single Hung in cold Northern ENERGY STAR counties?

This series is excluded from Northern ENERGY STAR eligibility (0 qualified options; floor U 0.28). Focus on South-Central, Southern glazing applications where SHGC 0.14-0.21 manages cooling loads.

What conductive BTU/hr difference separates Weathergard II - Vinyl Single Hung from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.28 U-Factor yields 168.0 BTU/hr conductive transfer (+27.3% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Which situations make Weathergard II - Vinyl Single Hung the wrong window or door choice?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Weathergard II - Vinyl Single Hung options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Is Weathergard II - Vinyl Single Hung suitable for sunbelt cooling-dominated homes?

Warm-climate homeowners have 60 Southern-approved options within Weathergard II - Vinyl Single Hung spanning SHGC down to 0.14. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

How many L.A.S. Enterprises Weathergard II - Vinyl Single Hung variants earn ENERGY STAR Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 60 Weathergard II - Vinyl Single Hung options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

What federal compliance checks govern 2026 Weathergard II - Vinyl Single Hung window swaps?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 L.A.S. Enterprises upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How can homeowners confirm delivered L.A.S. Enterprises Weathergard II - Vinyl Single Hung units match permits?

Confirm both the paper NFRC label and permanent corner glass etch match line LSE-M-11 and NFRC ID LSE before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for L.A.S. Enterprises Weathergard II - Vinyl Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros