L.A.S. Enterprises — Weathergard II - Vinyl Casement · Casement Windows
Across 5 L.A.S. Enterprises certified families, Weathergard II - Vinyl Casement supplies 44 Casement Windows configurations starting at 0.24 U-Factor and 0.13 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.25 U-Factor and 0.49 SHGC. Its thermal floor ranks #1,034 of 1,352 category entries—0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.24
- SHGC Range
- 0.13-0.49
- Certified Options
- 44
- Category Standing
- #1,034 of 1,352
How does L.A.S. Enterprises Weathergard II - Vinyl Casement compare thermally against Window peers?
L.A.S. Enterprises Weathergard II - Vinyl Casement achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Glazing breadth across Weathergard II - Vinyl Casement spans 44 NFRC test records (LSE), ranking #1,034 of 1,352 Window families (tied with 139 others at 0.24, more insulating than 13.2% of Window lines). Its 0.24 thermal floor compares at +0.05 against the Vinyl median (0.19).
Climate coverage for L.A.S. Enterprises Weathergard II - Vinyl Casement spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 4 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Lifecycle documentation anchors LSE to 2025-05-13 certification (FENSTAR issued 2018-10-03). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 144.0 BTU/hr conductive loss (+9.1% vs the 132.0 BTU/hr baseline at U=0.22).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 44 certified glazing combinations for Weathergard II - Vinyl Casement (NFRC LSE) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 4 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 42 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 40 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 40 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Target Windows and Doors — SL 3000 Single Hung | Vinyl | 0.24 | 0.20 | 42 |
| Target Windows and Doors — SL 3050 Single Slider | Vinyl | 0.24 | 0.20 | 42 |
| California Deluxe Windows Industries, Inc. — S-3725/3735 Single Slider | Vinyl | 0.24 | 0.12 | 40 |
| Comfort View Products, LLC — 1901 Picture Window | Vinyl | 0.24 | 0.21 | 40 |
| Crystal Window and Door Systems, Ltd. — 100 Series Double Hung | Vinyl | 0.24 | 0.16 | 48 |
What other certified series does L.A.S. Enterprises produce?
Compare other active L.A.S. Enterprises certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Weathergard II - Vinyl Double Hung
U-Factor 0.19–0.29 · 210 certified options.
Weathergard II - Vinyl Double Slider
U-Factor 0.19–0.29 · 210 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to L.A.S. Enterprises Weathergard II - Vinyl Casement appear below.
What U-Factor and SHGC range does L.A.S. Enterprises Weathergard II - Vinyl Casement achieve?
Across 44 tested NFRC glazing configurations, L.A.S. Enterprises Weathergard II - Vinyl Casement with Vinyl framing and Casement Single-Vent (CSSV) style reaches a 0.24 minimum U-Factor and 0.13-0.49 SHGC band. It places #1,034 among 1,352 Window series—more insulating than 13.2%.
Does L.A.S. Enterprises Weathergard II - Vinyl Casement qualify for the ENERGY STAR Northern Zone?
Northern qualification on Weathergard II - Vinyl Casement relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.24. Exactly 4 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.
What BTU/hr heat transfer results from Weathergard II - Vinyl Casement's 0.24 minimum U-Factor?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Weathergard II - Vinyl Casement at U 0.24 conducts 144.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
What are the practical limitations of specifying Weathergard II - Vinyl Casement?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Weathergard II - Vinyl Casement options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
How many Weathergard II - Vinyl Casement glazing packages pass Southern solar-heat rules?
Exactly 40 Weathergard II - Vinyl Casement options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.13 rather than higher 0.49 glass.
Does Weathergard II - Vinyl Casement carry EPA Most Efficient certification across its lineup?
All 44 Weathergard II - Vinyl Casement listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.
What federal compliance checks govern 2026 Weathergard II - Vinyl Casement window swaps?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
How can homeowners confirm delivered L.A.S. Enterprises Weathergard II - Vinyl Casement units match permits?
Confirm both the paper NFRC label and permanent corner glass etch match line LSE-M-1 and NFRC ID LSE before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for L.A.S. Enterprises Weathergard II - Vinyl Casement come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)