Skip to main content
Window · Vinyl Frame NFRC TAR · Product Line TAR-M-32

Target Windows and Doors — SL 3050 Single Slider · Single Slider

With a minimum U-Factor of 0.24—+0.04 compared against the 0.20 Window median—Target Windows and Doors SL 3050 Single Slider spans 42 tested options across Northern, North-Central, South-Central, Southern up to 0.31 U-Factor. Carrying NFRC CPD code TAR, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.20 and 0.50.

Min U-Factor
0.24
SHGC Range
0.20-0.50
Certified Options
42
Category Standing
#1,034 of 1,352

How does Target Windows and Doors SL 3050 Single Slider compare thermally against Window peers?

Target Windows and Doors SL 3050 Single Slider achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. SL 3050 Single SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing SL 3050 Single Slider (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

SL 3050 Single Slider Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across SL 3050 Single Slider spans 42 NFRC test records (TAR), ranking #1,034 of 1,352 Window families (tied with 139 others at 0.24, more insulating than 13.2% of Window lines). Its 0.24 thermal floor compares at +0.05 against the Vinyl median (0.19).

Regional qualification covers Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 6 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.24 U-Factor yields 144.0 BTU/hr transfer (+12.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2025-06-24 licensing and 2025-06-26 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 42 certified glazing combinations for SL 3050 Single Slider (NFRC TAR) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 6 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 12 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 21 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 30 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Target Windows and Doors produce?

Compare other active Target Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Target Windows and Doors SL 3050 Single Slider appear below.

How well does SL 3050 Single Slider by Target Windows and Doors insulate relative to Window benchmarks?

Testing puts Target Windows and Doors SL 3050 Single Slider at rank #1,034 of 1,352 Window entries with U 0.24 to 0.31 across 42 configurations. Solar heat gain ranges between 0.20 and 0.50 across Northern, North-Central, South-Central, Southern.

Which glazing options in Target Windows and Doors SL 3050 Single Slider meet Northern climate limits?

While Target Windows and Doors SL 3050 Single Slider misses the <= 0.22 prescriptive mark (floor U 0.24), 6 packages still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.

How does a 3x5 ft SL 3050 Single Slider window perform under a 40 deg F temperature drop?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), SL 3050 Single Slider at U 0.24 conducts 144.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What are the practical limitations of specifying SL 3050 Single Slider?

Cold-climate owners needing prescriptive U <= 0.22 should pass on SL 3050 Single Slider options exceeding U 0.22. Additionally, do not order Horizontal Slider (HSOX) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Can you install Target Windows and Doors SL 3050 Single Slider in Southern or South-Central zones?

Across Northern, North-Central, South-Central, Southern, 30 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Target Windows and Doors SL 3050 Single Slider, while total line SHGC reaches 0.50 in colder packages.

Does SL 3050 Single Slider carry EPA Most Efficient certification across its lineup?

SL 3050 Single Slider holds zero Most Efficient entries across its 42 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

Can homeowners claim Form 5695 credits on Target Windows and Doors SL 3050 Single Slider in 2026?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 SL 3050 Single Slider installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

Where are NFRC and IGCC identification marks located on SL 3050 Single Slider?

Confirm both the paper NFRC label and permanent corner glass etch match line TAR-M-32 and NFRC ID TAR before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Target Windows and Doors SL 3050 Single Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros