Skip to main content
Window · Vinyl Frame NFRC TAR · Product Line TAR-M-10 ENERGY STAR Most Efficient Eligible

Target Windows and Doors — 4000 Double Hung · Double Hung

Target Windows and Doors 4000 Double Hung is a Double Hung assembly with a Vinyl frame that reaches a minimum U-Factor of 0.21 across 24 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #742 of 1,352 in Window, its thermal floor is 0.01 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.17 to 0.47.

Min U-Factor
0.21
SHGC Range
0.17-0.47
Certified Options
24
Category Standing
#742 of 1,352

How does Target Windows and Doors 4000 Double Hung compare thermally against Window peers?

Target Windows and Doors 4000 Double Hung achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 4000 Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing 4000 Double Hung (U 0.21).249<=0.153140.16-0.182670.19-0.21This model: U 0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

4000 Double Hung Cohort StandingMin U-Factor 0.21 stands at rank #742 of 1,352, outperforming 38.6% of peers.Min U-Factor 0.21Rank #742 of 1,352 (38.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Target Windows and Doors 4000 Double Hung standing at #742 of 1,352 certified Window product series, tied with 88 others at 0.21, more insulating than 38.6% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.02 before selecting Low-E tiers.

Climate coverage for Target Windows and Doors 4000 Double Hung spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 3 configurations meet ENERGY STAR Most Efficient criteria while 8 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2025-08-28 and FENSTAR license 2025-06-24 inside EPA Version 7.0 tables. Heat transfer computes to 126.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 24 certified glazing combinations for 4000 Double Hung (NFRC TAR) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 8 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 14 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 16 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 16 packages (3 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Target Windows and Doors produce?

Compare other active Target Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Target Windows and Doors 4000 Double Hung appear below.

What thermal performance numbers separate Target Windows and Doors 4000 Double Hung from peers?

EPA ENERGY STAR v7.0 records 24 configurations for Target Windows and Doors 4000 Double Hung covering Northern, North-Central, South-Central, Southern, dropping down to U 0.21 versus a 0.20 Window median. Only 3 options earn Most Efficient status.

How does Target Windows and Doors 4000 Double Hung satisfy Version 7.0 Northern criteria?

Cold-climate buyers get 8 compliant Northern packages inside 4000 Double Hung, reaching down to U 0.21. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.28 options.

How do you calculate winter heat conduction for Target Windows and Doors 4000 Double Hung?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.21 U-Factor yields 126.0 BTU/hr conductive transfer (-4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What homeowner profiles are a poor match for Target Windows and Doors 4000 Double Hung?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 4000 Double Hung options exceeding U 0.22. Additionally, do not order Double-Hung (VSDH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

How many 4000 Double Hung glazing packages pass Southern solar-heat rules?

Warm-climate homeowners have 16 Southern-approved options within 4000 Double Hung spanning SHGC down to 0.17. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Does 4000 Double Hung carry EPA Most Efficient certification across its lineup?

Only 3 options out of 24 (12.5%) meet tighter Most Efficient U-Factor and SHGC thresholds in Target Windows and Doors 4000 Double Hung, usually requiring triple-pane or upgraded Low-E coatings.

Can homeowners claim Form 5695 credits on Target Windows and Doors 4000 Double Hung in 2026?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 4000 Double Hung installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do building inspectors verify 4000 Double Hung glass specs on job sites?

Verify NFRC ID TAR and series TAR-M-10 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Target Windows and Doors 4000 Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)