Crystal Window and Door Systems, Ltd. — 100 Series Double Hung · Double Hung
Crystal Window and Door Systems, Ltd. 100 Series Double Hung is a Double Hung assembly with a Vinyl frame that reaches a minimum U-Factor of 0.24 across 48 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #1,034 of 1,352 in Window, its thermal floor is 0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.16 to 0.43.
- Min U-Factor
- 0.24
- SHGC Range
- 0.16-0.43
- Certified Options
- 48
- Category Standing
- #1,034 of 1,352
How does Crystal Window and Door Systems, Ltd. 100 Series Double Hung compare thermally against Window peers?
Crystal Window and Door Systems, Ltd. 100 Series Double Hung achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Glazing breadth across 100 Series Double Hung spans 48 NFRC test records (CRW), ranking #1,034 of 1,352 Window families (tied with 139 others at 0.24, more insulating than 13.2% of Window lines). Its 0.24 thermal floor compares at +0.05 against the Vinyl median (0.19).
Regional qualification covers Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 1 Northern package qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Registry history records EPA FENSTAR licensing on 2026-09-29 and v7.0 data certification on 2026-11-02. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.24 conducts 144.0 BTU/hr (+12.0 BTU/hr vs the 0.22 ceiling).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 48 certified glazing combinations for 100 Series Double Hung (NFRC CRW) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 1 package (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 10 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 14 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 40 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Northeast Building Products Corporation — Camelot Pro-Series Horizontal Slider | Vinyl | 0.24 | 0.18 | 50 |
| Thermo-Twin Industries, Inc. — S-700/731 Welded Awning | Vinyl | 0.24 | 0.16 | 51 |
| L.A.S. Enterprises — Weathergard II - Vinyl Casement | Vinyl | 0.24 | 0.13 | 44 |
| L.A.S. Enterprises — Weathergard II - Vinyl Picture | Vinyl | 0.24 | 0.14 | 44 |
| Paradigm Window Solutions — 8381 Single Hung | Vinyl | 0.24 | 0.26 | 52 |
What other certified series does Crystal Window and Door Systems, Ltd. produce?
Compare other active Crystal Window and Door Systems, Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
9200 Tilt-Turn Window
U-Factor 0.19–0.32 · 1,520 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Crystal Window and Door Systems, Ltd. 100 Series Double Hung appear below.
Where does Crystal Window and Door Systems, Ltd. 100 Series Double Hung stand thermally among ENERGY STAR Window lines?
Built with Vinyl framing in Double-Hung (VSDH) style, Crystal Window and Door Systems, Ltd. 100 Series Double Hung offers 48 Version 7.0 configurations from U 0.24 up to 0.32, posting +0.04 against the Window median of 0.20 with 0 Most Efficient picks.
Which glazing options in Crystal Window and Door Systems, Ltd. 100 Series Double Hung meet Northern climate limits?
Because 100 Series Double Hung starts at 0.24 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 1 Northern package qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).
What BTU/hr heat transfer results from 100 Series Double Hung's 0.24 minimum U-Factor?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 100 Series Double Hung at U 0.24 conducts 144.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
What homeowner profiles are a poor match for Crystal Window and Door Systems, Ltd. 100 Series Double Hung?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 100 Series Double Hung options exceeding U 0.22. Additionally, do not order Double-Hung (VSDH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
How many 100 Series Double Hung glazing packages pass Southern solar-heat rules?
Yes, 100 Series Double Hung holds 40 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.16 SHGC in cooling climates.
Are all 48 100 Series Double Hung configurations ENERGY STAR Most Efficient?
All 48 100 Series Double Hung listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.
How do the 25C sunset and pre-1978 Lead RRP rules affect 100 Series Double Hung?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
How do you cross-check NFRC CRW and product line CRW-M-33 on delivery?
Confirm both the paper NFRC label and permanent corner glass etch match line CRW-M-33 and NFRC ID CRW before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Crystal Window and Door Systems, Ltd. 100 Series Double Hung come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)