Skip to main content
Window · Aluminum Frame NFRC CRW · Product Line CRW-M-74 ENERGY STAR Most Efficient Eligible

Crystal Window and Door Systems, Ltd. — 9200 Fixed Window · Picture Window

EPA ENERGY STAR Version 7.0 certifies 220 variants inside Crystal Window and Door Systems, Ltd. 9200 Fixed Window, combining Aluminum frame construction with U-Factors spanning 0.17 to 0.30 and SHGC 0.17 to 0.49. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #362 of 1,352 among 1,352 Window families and posts 0.06 Btu/hr·ft²·°F more insulating than the 0.23 Btu/hr·ft²·°F median among Aluminum peers.

Min U-Factor
0.17
SHGC Range
0.17-0.49
Certified Options
220
Category Standing
#362 of 1,352

How does Crystal Window and Door Systems, Ltd. 9200 Fixed Window compare thermally against Window peers?

Crystal Window and Door Systems, Ltd. 9200 Fixed Window achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 9200 Fixed WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 9200 Fixed Window (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

9200 Fixed Window Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Crystal Window and Door Systems, Ltd. 9200 Fixed Window at rank #362 of 1,352 (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.17-0.49 band.

Climate coverage for Crystal Window and Door Systems, Ltd. 9200 Fixed Window spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 12 configurations meet ENERGY STAR Most Efficient criteria while 24 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2026-11-02 and FENSTAR license 2026-09-29 inside EPA Version 7.0 tables. Heat transfer computes to 102.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 220 certified glazing combinations for 9200 Fixed Window (NFRC CRW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 24 packages (6 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 72 packages (12 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 93 packages (9 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 157 packages (9 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
DRUTEX S.A. — MB-79N/MB-86N SI Dual Action Window Aluminum 0.17 0.04 2,370
Value Windows & Doors — EuroTek Tilt and Turn Window Vinyl 0.17 0.13 219
ProVia LLC — Wood Clad Vinyl Double Hung Wood 0.17 0.05 231
ProVia LLC — Wood Clad Vinyl Casement Wood 0.17 0.06 232
Joyce Manufacturing Co. — VueLine 2 Lite Slider Vinyl 0.17 0.15 204

What other certified series does Crystal Window and Door Systems, Ltd. produce?

Compare other active Crystal Window and Door Systems, Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Crystal Window and Door Systems, Ltd. 9200 Fixed Window appear below.

Where does Crystal Window and Door Systems, Ltd. 9200 Fixed Window stand thermally among ENERGY STAR Window lines?

Crystal Window and Door Systems, Ltd. 9200 Fixed Window spans 220 certified configurations with U-Factors between 0.17 and 0.30 and SHGC values from 0.17 to 0.49. Ranked #362 of 1,352 Window families, it carries 12 Most Efficient options.

Can homeowners install 9200 Fixed Window in cold Northern ENERGY STAR counties?

Prescriptive Northern compliance covers 24 9200 Fixed Window packages (U floor 0.17, SHGC >= 0.17). Because the complete series stretches up to U 0.30, specify the cold-climate glass code explicitly.

How does a 3x5 ft 9200 Fixed Window window perform under a 40 deg F temperature drop?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 9200 Fixed Window at U 0.17 conducts 102.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Who should NOT choose Crystal Window and Door Systems, Ltd. 9200 Fixed Window for a residential project?

Do not specify 9200 Fixed Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 9200 Fixed Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Does 9200 Fixed Window meet Southern hot-climate SHGC caps (<= 0.23)?

Across Northern, North-Central, South-Central, Southern, 157 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Crystal Window and Door Systems, Ltd. 9200 Fixed Window, while total line SHGC reaches 0.49 in colder packages.

Are all 220 9200 Fixed Window configurations ENERGY STAR Most Efficient?

No. Exactly 12 of 220 configurations (5.5%) earn ENERGY STAR Most Efficient status in 9200 Fixed Window; the remaining standard v7.0 options pass base zone limits only.

What federal compliance checks govern 2026 9200 Fixed Window window swaps?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 9200 Fixed Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

What permanent glass etch marks verify 9200 Fixed Window after sticker removal?

Inspectors match the temporary NFRC sticker (U 0.17-0.30, SHGC 0.17-0.49) against permit drawings for line CRW-M-74. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Crystal Window and Door Systems, Ltd. 9200 Fixed Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros