DRUTEX S.A. — MB-79N/MB-86N SI Dual Action Window · Dual Action (Tilt Turn)
Positioning #362/1,352 in certified Window, DRUTEX S.A. MB-79N/MB-86N SI Dual Action Window pairs Aluminum frame construction with 2,370 glazing options rated between 0.04 and 0.38 SHGC across Northern, North-Central, South-Central, Southern. Across 40 certified DRUTEX S.A. product families, its thermal resistance spans 0.17 to 0.32 U-Factor and the line includes 417 ENERGY STAR Most Efficient packages (17.6% of line).
- Min U-Factor
- 0.17
- SHGC Range
- 0.04-0.38
- Certified Options
- 2,370
- Category Standing
- #362 of 1,352
How does DRUTEX S.A. MB-79N/MB-86N SI Dual Action Window compare thermally against Window peers?
DRUTEX S.A. MB-79N/MB-86N SI Dual Action Window achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places DRUTEX S.A. MB-79N/MB-86N SI Dual Action Window at rank #362 of 1,352 (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.04-0.38 band.
Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 417 configurations meet ENERGY STAR Most Efficient criteria while 488 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 102.0 BTU/hr (-22.7% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2023-04-03 and cert timestamp 2024-06-17.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 2,370 certified glazing combinations for MB-79N/MB-86N SI Dual Action Window (NFRC DRU) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 488 packages (133 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 1,371 packages (226 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 1,026 packages (115 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 1,724 packages (306 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Crystal Window and Door Systems, Ltd. — 9200 Fixed Window | Aluminum | 0.17 | 0.17 | 220 |
| Andersen Corporation — A-Series Specialty Windows - Sash-Set | Wood | 0.17 | 0.15 | 2,389 |
| Andersen Corporation — 400 Series Specialty Window - Elliptical | Wood | 0.17 | 0.14 | 2,428 |
| Andersen Corporation — 400 Series Specialty Windows - Circle/Oval | Wood | 0.17 | 0.15 | 2,472 |
| Pella Corporation — Pella Architect Clad Fixed Casement | Wood | 0.17 | 0.11 | 2,200 |
What other certified series does DRUTEX S.A. produce?
Compare other active DRUTEX S.A. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
IGLO Energy Alucover Fixed Window
U-Factor 0.14–0.20 · 10 certified options.
IGLO ENERGY Classic Fixed Window
U-Factor 0.15–0.32 · 3,527 certified options.
IGLO ENERGY Tilt and Slide Door
U-Factor 0.15–0.28 · 2,993 certified options.
MB-79N/MB-86N SI Fixed Window
U-Factor 0.15–0.32 · 2,540 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to DRUTEX S.A. MB-79N/MB-86N SI Dual Action Window appear below.
How efficient is DRUTEX S.A. MB-79N/MB-86N SI Dual Action Window compared with peer Window models?
Testing puts DRUTEX S.A. MB-79N/MB-86N SI Dual Action Window at rank #362 of 1,352 Window entries with U 0.17 to 0.32 across 2,370 configurations. Solar heat gain ranges between 0.04 and 0.38 across Northern, North-Central, South-Central, Southern.
How does DRUTEX S.A. MB-79N/MB-86N SI Dual Action Window satisfy Version 7.0 Northern criteria?
Yes. 488 packages in DRUTEX S.A. MB-79N/MB-86N SI Dual Action Window clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.
How much winter heat loss does MB-79N/MB-86N SI Dual Action Window conduct across a 15 sq ft opening?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 102.0 BTU/hr on MB-79N/MB-86N SI Dual Action Window's lowest-U package (0.17), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.
What homeowner profiles are a poor match for DRUTEX S.A. MB-79N/MB-86N SI Dual Action Window?
Skip MB-79N/MB-86N SI Dual Action Window if local historic preservation boards prohibit Aluminum profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on MB-79N/MB-86N SI Dual Action Window options exceeding U 0.22.
Does MB-79N/MB-86N SI Dual Action Window meet Southern hot-climate SHGC caps (<= 0.23)?
Across Northern, North-Central, South-Central, Southern, 1,724 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside DRUTEX S.A. MB-79N/MB-86N SI Dual Action Window, while total line SHGC reaches 0.38 in colder packages.
Which package tier in MB-79N/MB-86N SI Dual Action Window holds Most Efficient recognition?
Only 417 options out of 2,370 (17.6%) meet tighter Most Efficient U-Factor and SHGC thresholds in DRUTEX S.A. MB-79N/MB-86N SI Dual Action Window, usually requiring triple-pane or upgraded Low-E coatings.
What 2026 federal tax credit and Lead RRP rules apply to MB-79N/MB-86N SI Dual Action Window?
Any MB-79N/MB-86N SI Dual Action Window purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
How can homeowners confirm delivered DRUTEX S.A. MB-79N/MB-86N SI Dual Action Window units match permits?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code DRU and product line DRU-K-28, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for DRUTEX S.A. MB-79N/MB-86N SI Dual Action Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)