Skip to main content
Window · Wood Frame NFRC AND · Product Line AND-N-128 ENERGY STAR Most Efficient Eligible

Andersen Corporation — A-Series Specialty Windows - Sash-Set · Picture Window

Andersen Corporation engineered the A-Series Specialty Windows - Sash-Set Picture Window line for Northern, North-Central, South-Central, Southern, certifying 2,389 glass-spacer combinations from 0.17 to 0.32 U-Factor and 0.15 to 0.43 SHGC. Relative to other Wood models tracked under NFRC AND, its minimum U-Factor is 0.04 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.17
SHGC Range
0.15-0.43
Certified Options
2,389
Category Standing
#362 of 1,352

How does Andersen Corporation A-Series Specialty Windows - Sash-Set compare thermally against Window peers?

Andersen Corporation A-Series Specialty Windows - Sash-Set achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. A-Series Specialty Windows - Sash-SetHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing A-Series Specialty Windows - Sash-Set (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

A-Series Specialty Windows - Sash-Set Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 111 certified Andersen Corporation series, this Picture Window offers a 0.15 U-Factor adjustment span between 0.32 entry options and 0.17 top-performing glazing. Category standing is #362/1,352 (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%).

Climate coverage for Andersen Corporation A-Series Specialty Windows - Sash-Set spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 292 configurations meet ENERGY STAR Most Efficient criteria while 255 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.17 U-Factor yields 102.0 BTU/hr transfer (-30.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-01-08 licensing and 2024-03-07 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,389 certified glazing combinations for A-Series Specialty Windows - Sash-Set (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 255 packages (112 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 800 packages (224 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 784 packages (156 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 2,155 packages (224 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation A-Series Specialty Windows - Sash-Set appear below.

Where does Andersen Corporation A-Series Specialty Windows - Sash-Set stand thermally among ENERGY STAR Window lines?

Testing puts Andersen Corporation A-Series Specialty Windows - Sash-Set at rank #362 of 1,352 Window entries with U 0.17 to 0.32 across 2,389 configurations. Solar heat gain ranges between 0.15 and 0.43 across Northern, North-Central, South-Central, Southern.

Which glazing options in Andersen Corporation A-Series Specialty Windows - Sash-Set meet Northern climate limits?

Cold-climate buyers get 255 compliant Northern packages inside A-Series Specialty Windows - Sash-Set, reaching down to U 0.17. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

How do you calculate winter heat conduction for Andersen Corporation A-Series Specialty Windows - Sash-Set?

At U 0.17, a standard 3x5 ft (15 sq ft) A-Series Specialty Windows - Sash-Set opening transfers 102.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -30.0 BTU/hr difference.

Which situations make A-Series Specialty Windows - Sash-Set the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on A-Series Specialty Windows - Sash-Set options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

What Southern ENERGY STAR v7.0 options exist in A-Series Specialty Windows - Sash-Set?

Yes, A-Series Specialty Windows - Sash-Set holds 2,155 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.15 SHGC in cooling climates.

What glazing share inside A-Series Specialty Windows - Sash-Set qualifies as Most Efficient?

EPA lists 292 Most Efficient options (12.2% share) inside Andersen Corporation A-Series Specialty Windows - Sash-Set, out of 2,389 total Version 7.0 entries.

Can homeowners claim Form 5695 credits on Andersen Corporation A-Series Specialty Windows - Sash-Set in 2026?

Any A-Series Specialty Windows - Sash-Set purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do you cross-check NFRC AND and product line AND-N-128 on delivery?

Match the NFRC thermal sticker for code AND and line AND-N-128 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation A-Series Specialty Windows - Sash-Set come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros