Skip to main content
Window · Wood Frame NFRC KKM · Product Line KKM-N-132 ENERGY STAR Most Efficient Eligible

Kolbe and Kolbe Millwork Co., Inc — Heritage Push Out Casement MPL & SPL · Casement Windows

Across 57 Kolbe and Kolbe Millwork Co., Inc certified families, Heritage Push Out Casement MPL & SPL supplies 1,730 Casement Windows configurations starting at 0.17 U-Factor and 0.08 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.31 U-Factor and 0.39 SHGC. Its thermal floor ranks #362 of 1,352 category entries—0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.17
SHGC Range
0.08-0.39
Certified Options
1,730
Category Standing
#362 of 1,352

How does Kolbe and Kolbe Millwork Co., Inc Heritage Push Out Casement MPL & SPL compare thermally against Window peers?

Kolbe and Kolbe Millwork Co., Inc Heritage Push Out Casement MPL & SPL achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Heritage Push Out Casement MPL & SPLHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Heritage Push Out Casement MPL & SPL (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Heritage Push Out Casement MPL & SPL Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Heritage Push Out Casement MPL & SPL is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.17-0.31.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 848 configurations meet ENERGY STAR Most Efficient criteria while 328 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2026-05-04 and FENSTAR license 2018-02-20 inside EPA Version 7.0 tables. Heat transfer computes to 102.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,730 certified glazing combinations for Heritage Push Out Casement MPL & SPL (NFRC KKM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 328 packages (192 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 986 packages (824 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 1,260 packages (664 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 1,552 packages (688 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Kolbe and Kolbe Millwork Co., Inc produce?

Compare other active Kolbe and Kolbe Millwork Co., Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kolbe and Kolbe Millwork Co., Inc Heritage Push Out Casement MPL & SPL appear below.

How well does Heritage Push Out Casement MPL & SPL by Kolbe and Kolbe Millwork Co., Inc insulate relative to Window benchmarks?

Built with Wood framing in Casement Single-Vent (CSSV) style, Kolbe and Kolbe Millwork Co., Inc Heritage Push Out Casement MPL & SPL offers 1,730 Version 7.0 configurations from U 0.17 up to 0.31, posting -0.03 against the Window median of 0.20 with 848 Most Efficient picks.

Does Kolbe and Kolbe Millwork Co., Inc Heritage Push Out Casement MPL & SPL qualify for the ENERGY STAR Northern Zone?

Cold-climate buyers get 328 compliant Northern packages inside Heritage Push Out Casement MPL & SPL, reaching down to U 0.17. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.31 options.

What conductive BTU/hr difference separates Heritage Push Out Casement MPL & SPL from the 0.22 Northern rule?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Heritage Push Out Casement MPL & SPL at U 0.17 conducts 102.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Which situations make Heritage Push Out Casement MPL & SPL the wrong window or door choice?

Skip Heritage Push Out Casement MPL & SPL if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Heritage Push Out Casement MPL & SPL options exceeding U 0.22.

Can you install Kolbe and Kolbe Millwork Co., Inc Heritage Push Out Casement MPL & SPL in Southern or South-Central zones?

Warm-climate homeowners have 1,552 Southern-approved options within Heritage Push Out Casement MPL & SPL spanning SHGC down to 0.08. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Which package tier in Heritage Push Out Casement MPL & SPL holds Most Efficient recognition?

Only 848 options out of 1,730 (49.0%) meet tighter Most Efficient U-Factor and SHGC thresholds in Kolbe and Kolbe Millwork Co., Inc Heritage Push Out Casement MPL & SPL, usually requiring triple-pane or upgraded Low-E coatings.

How do the 25C sunset and pre-1978 Lead RRP rules affect Heritage Push Out Casement MPL & SPL?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Kolbe and Kolbe Millwork Co., Inc upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do you cross-check NFRC KKM and product line KKM-N-132 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code KKM and product line KKM-N-132, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kolbe and Kolbe Millwork Co., Inc Heritage Push Out Casement MPL & SPL come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros