Skip to main content
Window · Wood Frame NFRC PEL · Product Line PEL-N-1 ENERGY STAR Most Efficient Eligible

Pella Corporation — Pella Architect Clad Fixed Casement · Picture Window

Pella Corporation Pella Architect Clad Fixed Casement is a Picture Window assembly with a Wood frame that reaches a minimum U-Factor of 0.17 across 2,200 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #362 of 1,352 in Window, its thermal floor is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.11 to 0.52.

Min U-Factor
0.17
SHGC Range
0.11-0.52
Certified Options
2,200
Category Standing
#362 of 1,352

How does Pella Corporation Pella Architect Clad Fixed Casement compare thermally against Window peers?

Pella Corporation Pella Architect Clad Fixed Casement achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Pella Architect Clad Fixed CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Pella Architect Clad Fixed Casement (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Pella Architect Clad Fixed Casement Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 39 certified Pella Corporation series, this Picture Window offers a 0.15 U-Factor adjustment span between 0.32 entry options and 0.17 top-performing glazing. Category standing is #362/1,352 (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%).

Climate coverage for Pella Corporation Pella Architect Clad Fixed Casement spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 165 configurations meet ENERGY STAR Most Efficient criteria while 358 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-12-17 and FENSTAR license 2018-02-20 inside EPA Version 7.0 tables. Heat transfer computes to 102.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,200 certified glazing combinations for Pella Architect Clad Fixed Casement (NFRC PEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 358 packages (99 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 646 packages (129 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 955 packages (70 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 1,752 packages (94 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Pella Corporation produce?

Compare other active Pella Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Pella Corporation Pella Architect Clad Fixed Casement appear below.

How well does Pella Architect Clad Fixed Casement by Pella Corporation insulate relative to Window benchmarks?

Testing puts Pella Corporation Pella Architect Clad Fixed Casement at rank #362 of 1,352 Window entries with U 0.17 to 0.32 across 2,200 configurations. Solar heat gain ranges between 0.11 and 0.52 across Northern, North-Central, South-Central, Southern.

Can homeowners install Pella Architect Clad Fixed Casement in cold Northern ENERGY STAR counties?

Yes. 358 packages in Pella Corporation Pella Architect Clad Fixed Casement clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

What BTU/hr heat transfer results from Pella Architect Clad Fixed Casement's 0.17 minimum U-Factor?

At U 0.17, a standard 3x5 ft (15 sq ft) Pella Architect Clad Fixed Casement opening transfers 102.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -30.0 BTU/hr difference.

Which situations make Pella Architect Clad Fixed Casement the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Pella Architect Clad Fixed Casement options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Does Pella Architect Clad Fixed Casement meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 1,752 Southern-certified options inside Pella Corporation Pella Architect Clad Fixed Casement satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.52 SHGC on west-facing glass to avoid excess afternoon solar gain.

How many Pella Corporation Pella Architect Clad Fixed Casement variants earn ENERGY STAR Most Efficient?

Within Pella Architect Clad Fixed Casement, 7.5% (165 of 2,200) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

Can homeowners claim Form 5695 credits on Pella Corporation Pella Architect Clad Fixed Casement in 2026?

Any Pella Architect Clad Fixed Casement purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How can homeowners confirm delivered Pella Corporation Pella Architect Clad Fixed Casement units match permits?

Confirm both the paper NFRC label and permanent corner glass etch match line PEL-N-1 and NFRC ID PEL before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Pella Corporation Pella Architect Clad Fixed Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)