Window · Wood Frame NFRC AND · Product Line AND-N-148 ENERGY STAR Most Efficient Eligible

Andersen Corporation — 400 Series Specialty Windows - Circle/Oval · Picture Window

With a minimum U-Factor of 0.17—-0.03 compared against the 0.20 Window median—Andersen Corporation 400 Series Specialty Windows - Circle/Oval spans 2,472 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code AND, the Wood assembly includes 284 ENERGY STAR Most Efficient packages (11.5% of line) and offers SHGC packages between 0.15 and 0.53.

Min U-Factor
0.17
SHGC Range
0.15-0.53
Certified Options
2,472
Category Standing
#362 of 1,352

How does Andersen Corporation 400 Series Specialty Windows - Circle/Oval compare thermally against Window peers?

Andersen Corporation 400 Series Specialty Windows - Circle/Oval achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 400 Series Specialty Windows - Circle/OvalHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 400 Series Specialty Windows - Circle/Oval (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

400 Series Specialty Windows - Circle/Oval Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 400 Series Specialty Windows - Circle/Oval is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.17-0.32.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 284 configurations meet ENERGY STAR Most Efficient criteria while 654 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-03-07 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 102.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,472 certified glazing combinations for 400 Series Specialty Windows - Circle/Oval (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 654 packages (62 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 1,116 packages (104 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 1,210 packages (58 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 1,756 packages (228 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 400 Series Specialty Windows - Circle/Oval appear below.

How efficient is Andersen Corporation 400 Series Specialty Windows - Circle/Oval compared with peer Window models?

Testing puts Andersen Corporation 400 Series Specialty Windows - Circle/Oval at rank #362 of 1,352 Window entries with U 0.17 to 0.32 across 2,472 configurations. Solar heat gain ranges between 0.15 and 0.53 across Northern, North-Central, South-Central, Southern.

Which glazing options in Andersen Corporation 400 Series Specialty Windows - Circle/Oval meet Northern climate limits?

Andersen Corporation 400 Series Specialty Windows - Circle/Oval supplies 654 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

What conductive BTU/hr difference separates 400 Series Specialty Windows - Circle/Oval from the 0.22 Northern rule?

At U 0.17, a standard 3x5 ft (15 sq ft) 400 Series Specialty Windows - Circle/Oval opening transfers 102.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -30.0 BTU/hr difference.

What homeowner profiles are a poor match for Andersen Corporation 400 Series Specialty Windows - Circle/Oval?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 400 Series Specialty Windows - Circle/Oval options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Does 400 Series Specialty Windows - Circle/Oval meet Southern hot-climate SHGC caps (<= 0.23)?

Yes, 400 Series Specialty Windows - Circle/Oval holds 1,756 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.15 SHGC in cooling climates.

Are all 2,472 400 Series Specialty Windows - Circle/Oval configurations ENERGY STAR Most Efficient?

Within 400 Series Specialty Windows - Circle/Oval, 11.5% (284 of 2,472) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

What federal compliance checks govern 2026 400 Series Specialty Windows - Circle/Oval window swaps?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 400 Series Specialty Windows - Circle/Oval installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

What permanent glass etch marks verify 400 Series Specialty Windows - Circle/Oval after sticker removal?

Match the NFRC thermal sticker for code AND and line AND-N-148 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 400 Series Specialty Windows - Circle/Oval come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)