Skip to main content
Window · Vinyl Frame NFRC PWS · Product Line PWS-A-2

Paradigm Window Solutions — 8381 Single Hung · Single Hung

Paradigm Window Solutions engineered the 8381 Single Hung Single Hung line for Northern, North-Central, certifying 52 glass-spacer combinations from 0.24 to 0.26 U-Factor and 0.26 to 0.53 SHGC. Relative to other Vinyl models tracked under NFRC PWS, its minimum U-Factor is 0.05 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.24
SHGC Range
0.26-0.53
Certified Options
52
Category Standing
#1,034 of 1,352

How does Paradigm Window Solutions 8381 Single Hung compare thermally against Window peers?

Paradigm Window Solutions 8381 Single Hung achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 8381 Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 8381 Single Hung (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

8381 Single Hung Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 8381 Single Hung is 0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.24-0.26.

Evaluating climate compliance across Northern, North-Central separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 28 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2025-05-13 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 144.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 52 certified glazing combinations for 8381 Single Hung (NFRC PWS) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 28 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 24 packages (0 Most Eff.)
South-Central Not Listed <= 0.28 <= 0.23 0 packages (0 Most Eff.)
Southern Not Listed <= 0.32 <= 0.23 0 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Paradigm Window Solutions produce?

Compare other active Paradigm Window Solutions certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Paradigm Window Solutions 8381 Single Hung appear below.

What U-Factor and SHGC range does Paradigm Window Solutions 8381 Single Hung achieve?

Paradigm Window Solutions 8381 Single Hung spans 52 certified configurations with U-Factors between 0.24 and 0.26 and SHGC values from 0.26 to 0.53. Ranked #1,034 of 1,352 Window families, it carries 0 Most Efficient options.

Which glazing options in Paradigm Window Solutions 8381 Single Hung meet Northern climate limits?

Prescriptive Northern approval ends at U <= 0.22, above 8381 Single Hung's 0.24 minimum. However, 28 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

How do you calculate winter heat conduction for Paradigm Window Solutions 8381 Single Hung?

Using NFRC PWS U-Factor 0.24, a 15 sq ft Single-Hung (VSSH) assembly conducts 144.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+12.0 BTU/hr margin).

Which situations make 8381 Single Hung the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 8381 Single Hung options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

What Southern ENERGY STAR v7.0 options exist in 8381 Single Hung?

No—8381 Single Hung omits Southern ENERGY STAR certification (0 combinations), making it unsuitable for Gulf, desert, and South Atlantic cooling zones.

How many Paradigm Window Solutions 8381 Single Hung variants earn ENERGY STAR Most Efficient?

Zero glazing builds inside 8381 Single Hung's 52 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

Can homeowners claim Form 5695 credits on Paradigm Window Solutions 8381 Single Hung in 2026?

Any 8381 Single Hung purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do building inspectors verify 8381 Single Hung glass specs on job sites?

Inspectors match the temporary NFRC sticker (U 0.24-0.26, SHGC 0.26-0.53) against permit drawings for line PWS-A-2. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Paradigm Window Solutions 8381 Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)