Skip to main content
Window · Vinyl Frame NFRC TTN · Product Line TTN-K-24

Thermo-Twin Industries, Inc. — S-700/731 Welded Awning · Awning (Projected)

Positioning #1,034/1,352 in certified Window, Thermo-Twin Industries, Inc. S-700/731 Welded Awning pairs Vinyl frame construction with 51 glazing options rated between 0.16 and 0.42 SHGC across Northern, North-Central, South-Central, Southern. Across 6 certified Thermo-Twin Industries, Inc. product families, its thermal resistance spans 0.24 to 0.27 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.24
SHGC Range
0.16-0.42
Certified Options
51
Category Standing
#1,034 of 1,352

How does Thermo-Twin Industries, Inc. S-700/731 Welded Awning compare thermally against Window peers?

Thermo-Twin Industries, Inc. S-700/731 Welded Awning achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. S-700/731 Welded AwningHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing S-700/731 Welded Awning (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

S-700/731 Welded Awning Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across S-700/731 Welded Awning spans 51 NFRC test records (TTN), ranking #1,034 of 1,352 Window families (tied with 139 others at 0.24, more insulating than 13.2% of Window lines). Its 0.24 thermal floor compares at +0.05 against the Vinyl median (0.19).

Climate coverage for Thermo-Twin Industries, Inc. S-700/731 Welded Awning spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 6 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.24 U-Factor yields 144.0 BTU/hr transfer (+12.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-02-20 licensing and 2025-07-24 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 51 certified glazing combinations for S-700/731 Welded Awning (NFRC TTN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 6 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 19 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 26 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 26 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Thermo-Twin Industries, Inc. produce?

Compare other active Thermo-Twin Industries, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Thermo-Twin Industries, Inc. S-700/731 Welded Awning appear below.

Where does Thermo-Twin Industries, Inc. S-700/731 Welded Awning stand thermally among ENERGY STAR Window lines?

EPA ENERGY STAR v7.0 records 51 configurations for Thermo-Twin Industries, Inc. S-700/731 Welded Awning covering Northern, North-Central, South-Central, Southern, dropping down to U 0.24 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

How does Thermo-Twin Industries, Inc. S-700/731 Welded Awning satisfy Version 7.0 Northern criteria?

While Thermo-Twin Industries, Inc. S-700/731 Welded Awning misses the <= 0.22 prescriptive mark (floor U 0.24), 6 packages still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.

How do you calculate winter heat conduction for Thermo-Twin Industries, Inc. S-700/731 Welded Awning?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), S-700/731 Welded Awning at U 0.24 conducts 144.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What are the practical limitations of specifying S-700/731 Welded Awning?

Cold-climate owners needing prescriptive U <= 0.22 should pass on S-700/731 Welded Awning options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Can you install Thermo-Twin Industries, Inc. S-700/731 Welded Awning in Southern or South-Central zones?

Yes. 26 Southern-certified options inside Thermo-Twin Industries, Inc. S-700/731 Welded Awning satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.42 SHGC on west-facing glass to avoid excess afternoon solar gain.

Are all 51 S-700/731 Welded Awning configurations ENERGY STAR Most Efficient?

All 51 S-700/731 Welded Awning listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

How do the 25C sunset and pre-1978 Lead RRP rules affect S-700/731 Welded Awning?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 S-700/731 Welded Awning installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

Where are NFRC and IGCC identification marks located on S-700/731 Welded Awning?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code TTN and product line TTN-K-24, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Thermo-Twin Industries, Inc. S-700/731 Welded Awning come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros