Skip to main content
Window · Vinyl Frame NFRC TTN · Product Line TTN-K-26

Thermo-Twin Industries, Inc. — S-700/731 Welded 1-1/2" Picture Window · Picture Window

Across 6 Thermo-Twin Industries, Inc. certified families, S-700/731 Welded 1-1/2" Picture Window supplies 47 Picture Window configurations starting at 0.22 U-Factor and 0.21 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.26 U-Factor and 0.57 SHGC. Its thermal floor ranks #831 of 1,352 category entries—0.02 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.22
SHGC Range
0.21-0.57
Certified Options
47
Category Standing
#831 of 1,352

How does Thermo-Twin Industries, Inc. S-700/731 Welded 1-1/2" Picture Window compare thermally against Window peers?

Thermo-Twin Industries, Inc. S-700/731 Welded 1-1/2" Picture Window achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. S-700/731 Welded 1-1/2" Picture WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing S-700/731 Welded 1-1/2" Picture Window (U 0.22).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.221460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

S-700/731 Welded 1-1/2" Picture Window Cohort StandingMin U-Factor 0.22 stands at rank #831 of 1,352, outperforming 30.8% of peers.Min U-Factor 0.22Rank #831 of 1,352 (30.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), S-700/731 Welded 1-1/2" Picture Window reaches 0.22 on its lowest-conductivity package — #640 of 1,009 in Vinyl, tied with 75 others at 0.22, more insulating than 29.1% of Vinyl lines (+0.03 vs Vinyl peers). Pairing NFRC ID TTN across multi-pane fills shifts U-Factor from 0.26 down toward 0.22.

Climate coverage for Thermo-Twin Industries, Inc. S-700/731 Welded 1-1/2" Picture Window spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 34 combinations qualify in the Northern Zone alongside 10 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.22 U-Factor yields 132.0 BTU/hr transfer (matching the 0.22 Northern baseline). Manufacturer filing reflects 2018-02-20 licensing and 2024-07-30 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 47 certified glazing combinations for S-700/731 Welded 1-1/2" Picture Window (NFRC TTN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 34 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 12 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 10 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 10 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Thermo-Twin Industries, Inc. produce?

Compare other active Thermo-Twin Industries, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Thermo-Twin Industries, Inc. S-700/731 Welded 1-1/2" Picture Window appear below.

What U-Factor and SHGC range does Thermo-Twin Industries, Inc. S-700/731 Welded 1-1/2" Picture Window achieve?

EPA ENERGY STAR v7.0 records 47 configurations for Thermo-Twin Industries, Inc. S-700/731 Welded 1-1/2" Picture Window covering Northern, North-Central, South-Central, Southern, dropping down to U 0.22 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Does Thermo-Twin Industries, Inc. S-700/731 Welded 1-1/2" Picture Window qualify for the ENERGY STAR Northern Zone?

Yes. 34 packages in Thermo-Twin Industries, Inc. S-700/731 Welded 1-1/2" Picture Window clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.26.

What conductive BTU/hr difference separates S-700/731 Welded 1-1/2" Picture Window from the 0.22 Northern rule?

Using NFRC TTN U-Factor 0.22, a 15 sq ft Fixed Window (FIXD) assembly conducts 132.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+0.0 BTU/hr margin).

When should a buyer skip Thermo-Twin Industries, Inc. S-700/731 Welded 1-1/2" Picture Window and compare alternatives?

Do not specify S-700/731 Welded 1-1/2" Picture Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on S-700/731 Welded 1-1/2" Picture Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Can you install Thermo-Twin Industries, Inc. S-700/731 Welded 1-1/2" Picture Window in Southern or South-Central zones?

Across Northern, North-Central, South-Central, Southern, 10 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Thermo-Twin Industries, Inc. S-700/731 Welded 1-1/2" Picture Window, while total line SHGC reaches 0.57 in colder packages.

Which package tier in S-700/731 Welded 1-1/2" Picture Window holds Most Efficient recognition?

ENERGY STAR Most Efficient designation is absent across all 47 S-700/731 Welded 1-1/2" Picture Window options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

How do the 25C sunset and pre-1978 Lead RRP rules affect S-700/731 Welded 1-1/2" Picture Window?

Any S-700/731 Welded 1-1/2" Picture Window purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

What permanent glass etch marks verify S-700/731 Welded 1-1/2" Picture Window after sticker removal?

Inspectors match the temporary NFRC sticker (U 0.22-0.26, SHGC 0.21-0.57) against permit drawings for line TTN-K-26. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Thermo-Twin Industries, Inc. S-700/731 Welded 1-1/2" Picture Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)