KP Building Products Limited — 3900/3901 Hopper Window · Awning (Projected)
Across 15 KP Building Products Limited certified families, 3900/3901 Hopper Window supplies 2 Awning, Projected configurations starting at 0.26 U-Factor and 0.16 SHGC for South-Central, Southern, reaching up to 0.26 U-Factor and 0.18 SHGC. Its thermal floor ranks #1,256 of 1,352 category entries—0.06 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.26
- SHGC Range
- 0.16-0.18
- Certified Options
- 2
- Category Standing
- #1,256 of 1,352
How does KP Building Products Limited 3900/3901 Hopper Window compare thermally against Window peers?
KP Building Products Limited 3900/3901 Hopper Window achieves a 0.26 thermal floor across Window lines, placing #1,256 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 15 certified KP Building Products Limited series, this Awning, Projected offers a 0.00 U-Factor adjustment span between 0.26 entry options and 0.26 top-performing glazing. Category standing is #1,256/1,352 (tied with 35 others at 0.26, more insulating than 4.5% of Window lines).
Mapping NFRC SHGC values (0.16 to 0.18) against ENERGY STAR Version 7.0 targets approves South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.16 lowers cooling load.
Data provenance links certification 2025-02-11 and FENSTAR license 2018-06-13 inside EPA Version 7.0 tables. Heat transfer computes to 156.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 2 certified glazing combinations for 3900/3901 Hopper Window (NFRC FAR) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| North-Central | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 2 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 2 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Window Mart — 8500 Picture Window | Vinyl | 0.26 | 0.22 | 1 |
| Star Windows — 9230 Single Hung | Vinyl | 0.26 | 0.20 | 17 |
| Comfort View Products, LLC — 1920 Horizontal Slider | Vinyl | 0.26 | 0.20 | 33 |
| REHAU, S.A. DE C.V. — S190 Single Slider | Vinyl | 0.26 | 0.14 | 44 |
| Gerkin Windows and Doors — 6100 Single Hung | Vinyl | 0.26 | 0.14 | 91 |
What other certified series does KP Building Products Limited produce?
Compare other active KP Building Products Limited certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
2100/6500 Casement, 2120/6520 Fixed Casement
U-Factor 0.23–0.24 · 8 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to KP Building Products Limited 3900/3901 Hopper Window appear below.
How efficient is KP Building Products Limited 3900/3901 Hopper Window compared with peer Window models?
Testing puts KP Building Products Limited 3900/3901 Hopper Window at rank #1,256 of 1,352 Window entries with U 0.26 to 0.26 across 2 configurations. Solar heat gain ranges between 0.16 and 0.18 across South-Central, Southern.
Is 3900/3901 Hopper Window approved for Northern Zone heating climates?
No. Because 3900/3901 Hopper Window reaches only 0.26 U-Factor with 0 Northern combinations, it is not approved for ENERGY STAR Northern counties. Specify this Vinyl line strictly across South-Central, Southern cooling or mixed markets.
What BTU/hr heat transfer results from 3900/3901 Hopper Window's 0.26 minimum U-Factor?
Using NFRC FAR U-Factor 0.26, a 15 sq ft Projected Awning (PRAW) assembly conducts 156.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+24.0 BTU/hr margin).
When should a buyer skip KP Building Products Limited 3900/3901 Hopper Window and compare alternatives?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 3900/3901 Hopper Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
Can you install KP Building Products Limited 3900/3901 Hopper Window in Southern or South-Central zones?
Yes, 3900/3901 Hopper Window holds 2 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.16 SHGC in cooling climates.
What glazing share inside 3900/3901 Hopper Window qualifies as Most Efficient?
ENERGY STAR Most Efficient designation is absent across all 2 3900/3901 Hopper Window options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.
Can homeowners claim Form 5695 credits on KP Building Products Limited 3900/3901 Hopper Window in 2026?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
Where are NFRC and IGCC identification marks located on 3900/3901 Hopper Window?
Confirm both the paper NFRC label and permanent corner glass etch match line FAR-M-41 and NFRC ID FAR before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for KP Building Products Limited 3900/3901 Hopper Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)