Skip to main content
Window · Vinyl Frame NFRC FAR · Product Line FAR-M-24 ENERGY STAR Most Efficient Eligible

KP Building Products Limited — 5110/6110/7110 Awning · Awning (Projected)

EPA ENERGY STAR Version 7.0 certifies 14 variants inside KP Building Products Limited 5110/6110/7110 Awning, combining Vinyl frame construction with U-Factors spanning 0.18 to 0.24 and SHGC 0.15 to 0.42. Qualifying for Northern, North-Central, South-Central, Southern, this Awning, Projected family places #477 of 1,352 among 1,352 Window families and posts 0.01 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.18
SHGC Range
0.15-0.42
Certified Options
14
Category Standing
#477 of 1,352

How does KP Building Products Limited 5110/6110/7110 Awning compare thermally against Window peers?

KP Building Products Limited 5110/6110/7110 Awning achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 5110/6110/7110 AwningHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 5110/6110/7110 Awning (U 0.18).249<=0.153140.16-0.18This model: U 0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

5110/6110/7110 Awning Cohort StandingMin U-Factor 0.18 stands at rank #477 of 1,352, outperforming 58.4% of peers.Min U-Factor 0.18Rank #477 of 1,352 (58.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 5110/6110/7110 Awning spans 14 NFRC test records (FAR), ranking #477 of 1,352 Window families (tied with 86 others at 0.18, more insulating than 58.4% of Window lines, top 41.6%). Its 0.18 thermal floor compares at -0.01 against the Vinyl median (0.19).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 8 configurations meet ENERGY STAR Most Efficient criteria while 10 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.18 U-Factor yields 108.0 BTU/hr transfer (-24.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-06-13 licensing and 2025-02-11 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 14 certified glazing combinations for 5110/6110/7110 Awning (NFRC FAR) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 10 packages (4 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 13 packages (6 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 6 packages (2 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 6 packages (4 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Winchester Industries — Oxford / Bristol 751/251 Picture Window Vinyl 0.18 0.15 18
Vistaza Inc — Vi5 Series Fixed Window Vinyl 0.18 0.17 8
DRUTEX S.A. — IGLO LIGHT Tilt Turn Vinyl 0.18 0.22 4
DRUTEX S.A. — IGLO EDGE Awning Window Vinyl 0.18 0.14 26
DRUTEX S.A. — IGLO EDGE Casement Vinyl 0.18 0.14 26

What other certified series does KP Building Products Limited produce?

Compare other active KP Building Products Limited certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to KP Building Products Limited 5110/6110/7110 Awning appear below.

Where does KP Building Products Limited 5110/6110/7110 Awning stand thermally among ENERGY STAR Window lines?

Testing puts KP Building Products Limited 5110/6110/7110 Awning at rank #477 of 1,352 Window entries with U 0.18 to 0.24 across 14 configurations. Solar heat gain ranges between 0.15 and 0.42 across Northern, North-Central, South-Central, Southern.

Can homeowners install 5110/6110/7110 Awning in cold Northern ENERGY STAR counties?

Yes. 10 packages in KP Building Products Limited 5110/6110/7110 Awning clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.24.

How much winter heat loss does 5110/6110/7110 Awning conduct across a 15 sq ft opening?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 5110/6110/7110 Awning at U 0.18 conducts 108.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Which situations make 5110/6110/7110 Awning the wrong window or door choice?

Skip 5110/6110/7110 Awning if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 5110/6110/7110 Awning options exceeding U 0.22.

What Southern ENERGY STAR v7.0 options exist in 5110/6110/7110 Awning?

Across Northern, North-Central, South-Central, Southern, 6 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside KP Building Products Limited 5110/6110/7110 Awning, while total line SHGC reaches 0.42 in colder packages.

Are all 14 5110/6110/7110 Awning configurations ENERGY STAR Most Efficient?

Only 8 options out of 14 (57.1%) meet tighter Most Efficient U-Factor and SHGC thresholds in KP Building Products Limited 5110/6110/7110 Awning, usually requiring triple-pane or upgraded Low-E coatings.

How do the 25C sunset and pre-1978 Lead RRP rules affect 5110/6110/7110 Awning?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 KP Building Products Limited upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do you cross-check NFRC FAR and product line FAR-M-24 on delivery?

Confirm both the paper NFRC label and permanent corner glass etch match line FAR-M-24 and NFRC ID FAR before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for KP Building Products Limited 5110/6110/7110 Awning come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros