Skip to main content
Window · Vinyl Frame NFRC DRU · Product Line DRU-K-43 ENERGY STAR Most Efficient Eligible

DRUTEX S.A. — IGLO EDGE Awning Window · Awning (Projected)

Positioning #477/1,352 in certified Window, DRUTEX S.A. IGLO EDGE Awning Window pairs Vinyl frame construction with 26 glazing options rated between 0.14 and 0.28 SHGC across Northern, North-Central, South-Central, Southern. Across 40 certified DRUTEX S.A. product families, its thermal resistance spans 0.18 to 0.24 U-Factor and the line includes 16 ENERGY STAR Most Efficient packages (61.5% of line).

Min U-Factor
0.18
SHGC Range
0.14-0.28
Certified Options
26
Category Standing
#477 of 1,352

How does DRUTEX S.A. IGLO EDGE Awning Window compare thermally against Window peers?

DRUTEX S.A. IGLO EDGE Awning Window achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. IGLO EDGE Awning WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing IGLO EDGE Awning Window (U 0.18).249<=0.153140.16-0.18This model: U 0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

IGLO EDGE Awning Window Cohort StandingMin U-Factor 0.18 stands at rank #477 of 1,352, outperforming 58.4% of peers.Min U-Factor 0.18Rank #477 of 1,352 (58.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), IGLO EDGE Awning Window reaches 0.18 on its lowest-conductivity package — #354 of 1,009 in Vinyl, tied with 74 others at 0.18, more insulating than 57.6% of Vinyl lines, top 42.4% (-0.01 vs Vinyl peers). Pairing NFRC ID DRU across multi-pane fills shifts U-Factor from 0.24 down toward 0.18.

Mapping NFRC SHGC values (0.14 to 0.28) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 16 configurations meet ENERGY STAR Most Efficient criteria while 9 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.18 U-Factor yields 108.0 BTU/hr transfer (-24.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2023-04-03 licensing and 2025-07-10 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 26 certified glazing combinations for IGLO EDGE Awning Window (NFRC DRU) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 9 packages (6 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 26 packages (8 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 18 packages (2 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 18 packages (10 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does DRUTEX S.A. produce?

Compare other active DRUTEX S.A. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to DRUTEX S.A. IGLO EDGE Awning Window appear below.

What U-Factor and SHGC range does DRUTEX S.A. IGLO EDGE Awning Window achieve?

DRUTEX S.A. IGLO EDGE Awning Window spans 26 certified configurations with U-Factors between 0.18 and 0.24 and SHGC values from 0.14 to 0.28. Ranked #477 of 1,352 Window families, it carries 16 Most Efficient options.

How does DRUTEX S.A. IGLO EDGE Awning Window satisfy Version 7.0 Northern criteria?

Yes, 9 packages satisfy Northern ENERGY STAR Version 7.0 rules in IGLO EDGE Awning Window. Pairing multi-pane insulation down to 0.18 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How much winter heat loss does IGLO EDGE Awning Window conduct across a 15 sq ft opening?

At U 0.18, a standard 3x5 ft (15 sq ft) IGLO EDGE Awning Window opening transfers 108.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -24.0 BTU/hr difference.

When should a buyer skip DRUTEX S.A. IGLO EDGE Awning Window and compare alternatives?

Skip IGLO EDGE Awning Window if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on IGLO EDGE Awning Window options exceeding U 0.22.

Does IGLO EDGE Awning Window meet Southern hot-climate SHGC caps (<= 0.23)?

Exactly 18 IGLO EDGE Awning Window options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.14 rather than higher 0.28 glass.

Does IGLO EDGE Awning Window carry EPA Most Efficient certification across its lineup?

No. Exactly 16 of 26 configurations (61.5%) earn ENERGY STAR Most Efficient status in IGLO EDGE Awning Window; the remaining standard v7.0 options pass base zone limits only.

Do 2026 IGLO EDGE Awning Window installations qualify for IRS Section 25C tax credits?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do building inspectors verify IGLO EDGE Awning Window glass specs on job sites?

Match the NFRC thermal sticker for code DRU and line DRU-K-43 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for DRUTEX S.A. IGLO EDGE Awning Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros