Skip to main content
Window · Vinyl Frame NFRC VST · Product Line VST-K-8 ENERGY STAR Most Efficient Eligible

Vistaza Inc — Vi5 Series Fixed Window · Picture Window

With a minimum U-Factor of 0.18—-0.02 compared against the 0.20 Window median—Vistaza Inc Vi5 Series Fixed Window spans 8 tested options across Northern, North-Central, South-Central, Southern up to 0.28 U-Factor. Carrying NFRC CPD code VST, the Vinyl assembly includes 3 ENERGY STAR Most Efficient packages (37.5% of line) and offers SHGC packages between 0.17 and 0.34.

Min U-Factor
0.18
SHGC Range
0.17-0.34
Certified Options
8
Category Standing
#477 of 1,352

How does Vistaza Inc Vi5 Series Fixed Window compare thermally against Window peers?

Vistaza Inc Vi5 Series Fixed Window achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Vi5 Series Fixed WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Vi5 Series Fixed Window (U 0.18).249<=0.153140.16-0.18This model: U 0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Vi5 Series Fixed Window Cohort StandingMin U-Factor 0.18 stands at rank #477 of 1,352, outperforming 58.4% of peers.Min U-Factor 0.18Rank #477 of 1,352 (58.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Vistaza Inc Vi5 Series Fixed Window at rank #477 of 1,352 (tied with 86 others at 0.18, more insulating than 58.4% of Window lines, top 41.6%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.17-0.34 band.

Climate coverage for Vistaza Inc Vi5 Series Fixed Window spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 3 configurations meet ENERGY STAR Most Efficient criteria while 4 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 108.0 BTU/hr (-18.2% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2024-01-16 and cert timestamp 2024-02-06.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 8 certified glazing combinations for Vi5 Series Fixed Window (NFRC VST) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 4 packages (2 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 5 packages (3 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 6 packages (2 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 6 packages (2 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Vistaza Inc produce?

Compare other active Vistaza Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Vistaza Inc Vi5 Series Fixed Window appear below.

What U-Factor and SHGC range does Vistaza Inc Vi5 Series Fixed Window achieve?

Across 8 tested NFRC glazing configurations, Vistaza Inc Vi5 Series Fixed Window with Vinyl framing and Fixed Window (FIXD) style reaches a 0.18 minimum U-Factor and 0.17-0.34 SHGC band. It places #477 among 1,352 Window series—top 41.6%.

Is Vi5 Series Fixed Window approved for Northern Zone heating climates?

Yes. 4 packages in Vistaza Inc Vi5 Series Fixed Window clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.28.

How much winter heat loss does Vi5 Series Fixed Window conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.18 U-Factor yields 108.0 BTU/hr conductive transfer (-18.2% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What are the practical limitations of specifying Vi5 Series Fixed Window?

Do not specify Vi5 Series Fixed Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Vi5 Series Fixed Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

What Southern ENERGY STAR v7.0 options exist in Vi5 Series Fixed Window?

Warm-climate homeowners have 6 Southern-approved options within Vi5 Series Fixed Window spanning SHGC down to 0.17. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

How many Vistaza Inc Vi5 Series Fixed Window variants earn ENERGY STAR Most Efficient?

Only 3 options out of 8 (37.5%) meet tighter Most Efficient U-Factor and SHGC thresholds in Vistaza Inc Vi5 Series Fixed Window, usually requiring triple-pane or upgraded Low-E coatings.

What 2026 federal tax credit and Lead RRP rules apply to Vi5 Series Fixed Window?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Vi5 Series Fixed Window retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

What permanent glass etch marks verify Vi5 Series Fixed Window after sticker removal?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code VST and product line VST-K-8, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Vistaza Inc Vi5 Series Fixed Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)