Neuma Door — Inswing Transom · Transom
Neuma Door engineered the Inswing Transom Transom line for South-Central, Southern, certifying 12 glass-spacer combinations from 0.26 to 0.32 U-Factor and 0.17 to 0.23 SHGC. Relative to other Composite models tracked under NFRC NND, its minimum U-Factor is 0.04 Btu/hr·ft²·°F less insulating than the 0.22 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.26
- SHGC Range
- 0.17-0.23
- Certified Options
- 12
- Category Standing
- #1,256 of 1,352
How does Neuma Door Inswing Transom compare thermally against Window peers?
Neuma Door Inswing Transom achieves a 0.26 thermal floor across Window lines, placing #1,256 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Neuma Door Inswing Transom at rank #1,256 of 1,352 (tied with 35 others at 0.26, more insulating than 4.5% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.17-0.23 band.
Regional qualification covers South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.17 lowers cooling load.
Data provenance links certification 2025-03-11 and FENSTAR license 2018-01-23 inside EPA Version 7.0 tables. Heat transfer computes to 156.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 12 certified glazing combinations for Inswing Transom (NFRC NND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| North-Central | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 9 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 12 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Star Windows — 9230 Single Hung | Vinyl | 0.26 | 0.20 | 17 |
| Value Windows & Doors — AUC-XO Horizontal Slider | Aluminum | 0.26 | 0.13 | 20 |
| KP Building Products Limited — 3900/3901 Hopper Window | Vinyl | 0.26 | 0.16 | 2 |
| Window Mart — 8500 Picture Window | Vinyl | 0.26 | 0.22 | 1 |
| Comfort View Products, LLC — 1920 Horizontal Slider | Vinyl | 0.26 | 0.20 | 33 |
What other certified series does Neuma Door produce?
Compare other active Neuma Door certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Inswing/Outswing Hinged Entry Door
U-Factor 0.14–0.28 · 7,646 certified options.
Neuma Hinged Door
U-Factor 0.16–0.28 · 195 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Neuma Door Inswing Transom appear below.
Where does Neuma Door Inswing Transom stand thermally among ENERGY STAR Window lines?
Across 12 tested NFRC glazing configurations, Neuma Door Inswing Transom with Composite framing and Fixed Transom (FXTR) style reaches a 0.26 minimum U-Factor and 0.17-0.23 SHGC band. It places #1,256 among 1,352 Window series—more insulating than 4.5%.
Does Neuma Door Inswing Transom qualify for the ENERGY STAR Northern Zone?
No—with 0 Northern packages and a 0.26 thermal floor, Neuma Door Inswing Transom targets warmer South-Central, Southern climates instead of cold Northern installations.
How does a 3x5 ft Inswing Transom window perform under a 40 deg F temperature drop?
At U 0.26, a standard 3x5 ft (15 sq ft) Inswing Transom opening transfers 156.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +24.0 BTU/hr difference.
When should a buyer skip Neuma Door Inswing Transom and compare alternatives?
Do not specify Inswing Transom without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Inswing Transom options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
Is Inswing Transom suitable for sunbelt cooling-dominated homes?
Yes. 12 Southern-certified options inside Neuma Door Inswing Transom satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.23 SHGC on west-facing glass to avoid excess afternoon solar gain.
Are all 12 Inswing Transom configurations ENERGY STAR Most Efficient?
All 12 Inswing Transom listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.
What federal compliance checks govern 2026 Inswing Transom window swaps?
In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Inswing Transom retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.
How can homeowners confirm delivered Neuma Door Inswing Transom units match permits?
Verify NFRC ID NND and series NND-M-12 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Neuma Door Inswing Transom come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)