Andersen Corporation — 400 Series Tilt-Wash Double-Hung Insert Window · Double Hung
Andersen Corporation 400 Series Tilt-Wash Double-Hung Insert Window is a Double Hung assembly with a Wood frame that reaches a minimum U-Factor of 0.26 across 326 certified glazing configurations covering South-Central, Southern. Ranked #1,256 of 1,352 in Window, its thermal floor is 0.06 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.14 to 0.23.
- Min U-Factor
- 0.26
- SHGC Range
- 0.14-0.23
- Certified Options
- 326
- Category Standing
- #1,256 of 1,352
How does Andersen Corporation 400 Series Tilt-Wash Double-Hung Insert Window compare thermally against Window peers?
Andersen Corporation 400 Series Tilt-Wash Double-Hung Insert Window achieves a 0.26 thermal floor across Window lines, placing #1,256 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Relative to Window assemblies nationwide (median U 0.20), 400 Series Tilt-Wash Double-Hung Insert Window is 0.06 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.26-0.32.
Evaluating climate compliance across South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.14 lowers cooling load.
Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.26 U-Factor yields 156.0 BTU/hr transfer (+24.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-01-08 licensing and 2025-04-11 certification.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 326 certified glazing combinations for 400 Series Tilt-Wash Double-Hung Insert Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| North-Central | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 60 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 326 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Windsor Windows and Doors — Pinnacle Clad Win-Pac | Wood | 0.26 | 0.14 | 267 |
| Lincoln Wood Products, Inc. — Clad Door Transom | Wood | 0.26 | 0.14 | 102 |
| JELD-WEN, inc. — Siteline EX Clad Wood Horizontal Slider | Wood | 0.26 | 0.12 | 89 |
| Harvey Industries, Inc. — Majesty Casement Window | Wood | 0.26 | 0.16 | 59 |
| Lincoln Wood Products, Inc. — Wood Awning - Push-Out & Crank-Out | Wood | 0.26 | 0.15 | 37 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 400 Series Tilt-Wash Double-Hung Insert Window appear below.
How well does 400 Series Tilt-Wash Double-Hung Insert Window by Andersen Corporation insulate relative to Window benchmarks?
EPA ENERGY STAR v7.0 records 326 configurations for Andersen Corporation 400 Series Tilt-Wash Double-Hung Insert Window covering South-Central, Southern, dropping down to U 0.26 versus a 0.20 Window median. Only 0 options earn Most Efficient status.
Can homeowners install 400 Series Tilt-Wash Double-Hung Insert Window in cold Northern ENERGY STAR counties?
No—with 0 Northern packages and a 0.26 thermal floor, Andersen Corporation 400 Series Tilt-Wash Double-Hung Insert Window targets warmer South-Central, Southern climates instead of cold Northern installations.
What conductive BTU/hr difference separates 400 Series Tilt-Wash Double-Hung Insert Window from the 0.22 Northern rule?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.26 U-Factor yields 156.0 BTU/hr conductive transfer (+18.2% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
What are the practical limitations of specifying 400 Series Tilt-Wash Double-Hung Insert Window?
Skip 400 Series Tilt-Wash Double-Hung Insert Window if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 400 Series Tilt-Wash Double-Hung Insert Window options exceeding U 0.22.
Can you install Andersen Corporation 400 Series Tilt-Wash Double-Hung Insert Window in Southern or South-Central zones?
Across South-Central, Southern, 326 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Andersen Corporation 400 Series Tilt-Wash Double-Hung Insert Window, while total line SHGC reaches 0.23 in colder packages.
Which package tier in 400 Series Tilt-Wash Double-Hung Insert Window holds Most Efficient recognition?
Zero glazing builds inside 400 Series Tilt-Wash Double-Hung Insert Window's 326 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.
What federal compliance checks govern 2026 400 Series Tilt-Wash Double-Hung Insert Window window swaps?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
Where are NFRC and IGCC identification marks located on 400 Series Tilt-Wash Double-Hung Insert Window?
Confirm both the paper NFRC label and permanent corner glass etch match line AND-N-132 and NFRC ID AND before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 400 Series Tilt-Wash Double-Hung Insert Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)