Window · Wood Frame NFRC WIN · Product Line WIN-N-150

Windsor Windows and Doors — Pinnacle Clad Win-Pac · Double Hung

EPA ENERGY STAR Version 7.0 certifies 267 variants inside Windsor Windows and Doors Pinnacle Clad Win-Pac, combining Wood frame construction with U-Factors spanning 0.26 to 0.32 and SHGC 0.14 to 0.23. Qualifying for South-Central, Southern, this Double Hung family places #1,256 of 1,352 among 1,352 Window families and posts 0.05 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median among Wood peers.

Min U-Factor
0.26
SHGC Range
0.14-0.23
Certified Options
267
Category Standing
#1,256 of 1,352

How does Windsor Windows and Doors Pinnacle Clad Win-Pac compare thermally against Window peers?

Windsor Windows and Doors Pinnacle Clad Win-Pac achieves a 0.26 thermal floor across Window lines, placing #1,256 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Pinnacle Clad Win-PacHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Pinnacle Clad Win-Pac (U 0.26).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.26310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Pinnacle Clad Win-Pac Cohort StandingMin U-Factor 0.26 stands at rank #1,256 of 1,352, outperforming 4.5% of peers.Min U-Factor 0.26Rank #1,256 of 1,352 (4.5% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Windsor Windows and Doors Pinnacle Clad Win-Pac standing at #1,256 of 1,352 certified Window product series, tied with 35 others at 0.26, more insulating than 4.5% of Window lines. Comparing Wood profiles alone (median 0.21) shows +0.05 before selecting Low-E tiers.

Zone eligibility across EPA boundaries reaches 2 markets (South-Central, Southern). Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.14 lowers cooling load.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 156.0 BTU/hr (+18.2% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2024-04-10.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 267 certified glazing combinations for Pinnacle Clad Win-Pac (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 44 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 267 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Windsor Windows and Doors produce?

Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Pinnacle Clad Win-Pac appear below.

What U-Factor and SHGC range does Windsor Windows and Doors Pinnacle Clad Win-Pac achieve?

Testing puts Windsor Windows and Doors Pinnacle Clad Win-Pac at rank #1,256 of 1,352 Window entries with U 0.26 to 0.32 across 267 configurations. Solar heat gain ranges between 0.14 and 0.23 across South-Central, Southern.

How does Windsor Windows and Doors Pinnacle Clad Win-Pac satisfy Version 7.0 Northern criteria?

No—with 0 Northern packages and a 0.26 thermal floor, Windsor Windows and Doors Pinnacle Clad Win-Pac targets warmer South-Central, Southern climates instead of cold Northern installations.

How does a 3x5 ft Pinnacle Clad Win-Pac window perform under a 40 deg F temperature drop?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.26 U-Factor yields 156.0 BTU/hr conductive transfer (+18.2% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Who should NOT choose Windsor Windows and Doors Pinnacle Clad Win-Pac for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Pinnacle Clad Win-Pac options exceeding U 0.22. Additionally, do not order Double-Hung (VSDH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Is Pinnacle Clad Win-Pac suitable for sunbelt cooling-dominated homes?

Across South-Central, Southern, 267 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Windsor Windows and Doors Pinnacle Clad Win-Pac, while total line SHGC reaches 0.23 in colder packages.

How many Windsor Windows and Doors Pinnacle Clad Win-Pac variants earn ENERGY STAR Most Efficient?

No. Zero of the 267 configurations in Windsor Windows and Doors Pinnacle Clad Win-Pac hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

Can homeowners claim Form 5695 credits on Windsor Windows and Doors Pinnacle Clad Win-Pac in 2026?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Windsor Windows and Doors upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How can homeowners confirm delivered Windsor Windows and Doors Pinnacle Clad Win-Pac units match permits?

Confirm both the paper NFRC label and permanent corner glass etch match line WIN-N-150 and NFRC ID WIN before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Pinnacle Clad Win-Pac come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros