Andersen Corporation — 400 Series Woodwright® Double- Hung Insert Window · Double Hung
Andersen Corporation engineered the 400 Series Woodwright® Double- Hung Insert Window Double Hung line for South-Central, Southern, certifying 333 glass-spacer combinations from 0.26 to 0.32 U-Factor and 0.15 to 0.23 SHGC. Relative to other Wood models tracked under NFRC AND, its minimum U-Factor is 0.05 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.26
- SHGC Range
- 0.15-0.23
- Certified Options
- 333
- Category Standing
- #1,256 of 1,352
How does Andersen Corporation 400 Series Woodwright® Double- Hung Insert Window compare thermally against Window peers?
Andersen Corporation 400 Series Woodwright® Double- Hung Insert Window achieves a 0.26 thermal floor across Window lines, placing #1,256 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Wood cohort (0.21 median U-Factor), 400 Series Woodwright® Double- Hung Insert Window reaches 0.26 on its lowest-conductivity package — #352 of 408 in Wood, tied with 24 others at 0.26, more insulating than 7.8% of Wood lines (+0.05 vs Wood peers). Pairing NFRC ID AND across multi-pane fills shifts U-Factor from 0.32 down toward 0.26.
Zone eligibility across EPA boundaries reaches 2 markets (South-Central, Southern). Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.15 lowers cooling load.
Lifecycle documentation anchors AND to 2024-03-20 certification (FENSTAR issued 2019-01-08). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 156.0 BTU/hr conductive loss (+18.2% vs the 132.0 BTU/hr baseline at U=0.22).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 333 certified glazing combinations for 400 Series Woodwright® Double- Hung Insert Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| North-Central | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 34 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 333 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Windsor Windows and Doors — Pinnacle Clad Win-Pac | Wood | 0.26 | 0.14 | 267 |
| Lincoln Wood Products, Inc. — Clad Door Transom | Wood | 0.26 | 0.14 | 102 |
| JELD-WEN, inc. — Siteline EX Clad Wood Horizontal Slider | Wood | 0.26 | 0.12 | 89 |
| Harvey Industries, Inc. — Majesty Casement Window | Wood | 0.26 | 0.16 | 59 |
| Lincoln Wood Products, Inc. — Wood Awning - Push-Out & Crank-Out | Wood | 0.26 | 0.15 | 37 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 400 Series Woodwright® Double- Hung Insert Window appear below.
Where does Andersen Corporation 400 Series Woodwright® Double- Hung Insert Window stand thermally among ENERGY STAR Window lines?
Across 333 tested NFRC glazing configurations, Andersen Corporation 400 Series Woodwright® Double- Hung Insert Window with Wood framing and Double-Hung (VSDH) style reaches a 0.26 minimum U-Factor and 0.15-0.23 SHGC band. It places #1,256 among 1,352 Window series—more insulating than 4.5%.
Which glazing options in Andersen Corporation 400 Series Woodwright® Double- Hung Insert Window meet Northern climate limits?
Northern Zone certification is absent for 400 Series Woodwright® Double- Hung Insert Window (0 qualifying options, min U 0.26). Install this Double-Hung (VSDH) product only within South-Central, Southern regions where lower SHGC caps apply.
What conductive BTU/hr difference separates 400 Series Woodwright® Double- Hung Insert Window from the 0.22 Northern rule?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 400 Series Woodwright® Double- Hung Insert Window at U 0.26 conducts 156.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
When should a buyer skip Andersen Corporation 400 Series Woodwright® Double- Hung Insert Window and compare alternatives?
Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 400 Series Woodwright® Double- Hung Insert Window options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.
How many 400 Series Woodwright® Double- Hung Insert Window glazing packages pass Southern solar-heat rules?
Yes, 400 Series Woodwright® Double- Hung Insert Window holds 333 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.15 SHGC in cooling climates.
Does 400 Series Woodwright® Double- Hung Insert Window carry EPA Most Efficient certification across its lineup?
All 333 400 Series Woodwright® Double- Hung Insert Window listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.
What federal compliance checks govern 2026 400 Series Woodwright® Double- Hung Insert Window window swaps?
Any 400 Series Woodwright® Double- Hung Insert Window purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
How do building inspectors verify 400 Series Woodwright® Double- Hung Insert Window glass specs on job sites?
Match the NFRC thermal sticker for code AND and line AND-N-74 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 400 Series Woodwright® Double- Hung Insert Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)