Window · Wood Frame NFRC TVW · Product Line TVW-A-165

Lincoln Wood Products, Inc. — Wood Awning - Push-Out & Crank-Out · Awning (Projected)

Lincoln Wood Products, Inc. engineered the Wood Awning - Push-Out & Crank-Out Awning, Projected line for South-Central, Southern, certifying 37 glass-spacer combinations from 0.26 to 0.32 U-Factor and 0.15 to 0.23 SHGC. Relative to other Wood models tracked under NFRC TVW, its minimum U-Factor is 0.05 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.26
SHGC Range
0.15-0.23
Certified Options
37
Category Standing
#1,256 of 1,352

How does Lincoln Wood Products, Inc. Wood Awning - Push-Out & Crank-Out compare thermally against Window peers?

Lincoln Wood Products, Inc. Wood Awning - Push-Out & Crank-Out achieves a 0.26 thermal floor across Window lines, placing #1,256 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Wood Awning - Push-Out & Crank-OutHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Wood Awning - Push-Out & Crank-Out (U 0.26).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.26310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Wood Awning - Push-Out & Crank-Out Cohort StandingMin U-Factor 0.26 stands at rank #1,256 of 1,352, outperforming 4.5% of peers.Min U-Factor 0.26Rank #1,256 of 1,352 (4.5% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Wood Awning - Push-Out & Crank-Out is 0.06 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.26-0.32.

Climate coverage for Lincoln Wood Products, Inc. Wood Awning - Push-Out & Crank-Out spans South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.15 lowers cooling load.

Data provenance links certification 2024-04-09 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 156.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 37 certified glazing combinations for Wood Awning - Push-Out & Crank-Out (NFRC TVW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 7 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 37 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Lincoln Wood Products, Inc. produce?

Compare other active Lincoln Wood Products, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Lincoln Wood Products, Inc. Wood Awning - Push-Out & Crank-Out appear below.

How well does Wood Awning - Push-Out & Crank-Out by Lincoln Wood Products, Inc. insulate relative to Window benchmarks?

Lincoln Wood Products, Inc. Wood Awning - Push-Out & Crank-Out spans 37 certified configurations with U-Factors between 0.26 and 0.32 and SHGC values from 0.15 to 0.23. Ranked #1,256 of 1,352 Window families, it carries 0 Most Efficient options.

How does Lincoln Wood Products, Inc. Wood Awning - Push-Out & Crank-Out satisfy Version 7.0 Northern criteria?

No—with 0 Northern packages and a 0.26 thermal floor, Lincoln Wood Products, Inc. Wood Awning - Push-Out & Crank-Out targets warmer South-Central, Southern climates instead of cold Northern installations.

What conductive BTU/hr difference separates Wood Awning - Push-Out & Crank-Out from the 0.22 Northern rule?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Wood Awning - Push-Out & Crank-Out at U 0.26 conducts 156.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Which situations make Wood Awning - Push-Out & Crank-Out the wrong window or door choice?

Skip Wood Awning - Push-Out & Crank-Out if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Wood Awning - Push-Out & Crank-Out options exceeding U 0.22.

Does Wood Awning - Push-Out & Crank-Out meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 37 Southern-certified options inside Lincoln Wood Products, Inc. Wood Awning - Push-Out & Crank-Out satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.23 SHGC on west-facing glass to avoid excess afternoon solar gain.

How many Lincoln Wood Products, Inc. Wood Awning - Push-Out & Crank-Out variants earn ENERGY STAR Most Efficient?

No. Zero of the 37 configurations in Lincoln Wood Products, Inc. Wood Awning - Push-Out & Crank-Out hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

Do 2026 Wood Awning - Push-Out & Crank-Out installations qualify for IRS Section 25C tax credits?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Wood Awning - Push-Out & Crank-Out installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do building inspectors verify Wood Awning - Push-Out & Crank-Out glass specs on job sites?

Match the NFRC thermal sticker for code TVW and line TVW-A-165 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Lincoln Wood Products, Inc. Wood Awning - Push-Out & Crank-Out come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros