Window · Wood Frame NFRC TVW · Product Line TVW-A-160 ENERGY STAR Most Efficient Eligible

Lincoln Wood Products, Inc. — Clad Casement Studio (Transom) - Crank-Out & Push-Out · Picture Window

Lincoln Wood Products, Inc. engineered the Clad Casement Studio (Transom) - Crank-Out & Push-Out Picture Window line for Northern, North-Central, South-Central, Southern, certifying 598 glass-spacer combinations from 0.19 to 0.32 U-Factor and 0.16 to 0.33 SHGC. Relative to other Wood models tracked under NFRC TVW, its minimum U-Factor is 0.02 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.19
SHGC Range
0.16-0.33
Certified Options
598
Category Standing
#564 of 1,352

How does Lincoln Wood Products, Inc. Clad Casement Studio (Transom) - Crank-Out & Push-Out compare thermally against Window peers?

Lincoln Wood Products, Inc. Clad Casement Studio (Transom) - Crank-Out & Push-Out achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Clad Casement Studio (Transom) - Crank-Out & Push-OutHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Clad Casement Studio (Transom) - Crank-Out & Push-Out (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Clad Casement Studio (Transom) - Crank-Out & Push-Out Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Lincoln Wood Products, Inc. Clad Casement Studio (Transom) - Crank-Out & Push-Out standing at #564 of 1,352 certified Window product series, tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%. Comparing Wood profiles alone (median 0.21) shows -0.02 before selecting Low-E tiers.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 42 configurations meet ENERGY STAR Most Efficient criteria while 44 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.19 U-Factor yields 114.0 BTU/hr transfer (-18.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-04-05 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 598 certified glazing combinations for Clad Casement Studio (Transom) - Crank-Out & Push-Out (NFRC TVW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 44 packages (17 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 152 packages (31 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 270 packages (17 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 522 packages (28 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Lincoln Wood Products, Inc. produce?

Compare other active Lincoln Wood Products, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Lincoln Wood Products, Inc. Clad Casement Studio (Transom) - Crank-Out & Push-Out appear below.

What thermal performance numbers separate Lincoln Wood Products, Inc. Clad Casement Studio (Transom) - Crank-Out & Push-Out from peers?

Lincoln Wood Products, Inc. Clad Casement Studio (Transom) - Crank-Out & Push-Out spans 598 certified configurations with U-Factors between 0.19 and 0.32 and SHGC values from 0.16 to 0.33. Ranked #564 of 1,352 Window families, it carries 42 Most Efficient options.

Which glazing options in Lincoln Wood Products, Inc. Clad Casement Studio (Transom) - Crank-Out & Push-Out meet Northern climate limits?

Lincoln Wood Products, Inc. Clad Casement Studio (Transom) - Crank-Out & Push-Out supplies 44 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

What conductive BTU/hr difference separates Clad Casement Studio (Transom) - Crank-Out & Push-Out from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.19 U-Factor yields 114.0 BTU/hr conductive transfer (-13.6% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What homeowner profiles are a poor match for Lincoln Wood Products, Inc. Clad Casement Studio (Transom) - Crank-Out & Push-Out?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Clad Casement Studio (Transom) - Crank-Out & Push-Out options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Does Clad Casement Studio (Transom) - Crank-Out & Push-Out meet Southern hot-climate SHGC caps (<= 0.23)?

Exactly 522 Clad Casement Studio (Transom) - Crank-Out & Push-Out options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.16 rather than higher 0.33 glass.

Which package tier in Clad Casement Studio (Transom) - Crank-Out & Push-Out holds Most Efficient recognition?

Not every package qualifies: 42 of 598 Clad Casement Studio (Transom) - Crank-Out & Push-Out glazing builds earn Most Efficient recognition (7.0%), while other variants sit on the standard Version 7.0 tier.

Can homeowners claim Form 5695 credits on Lincoln Wood Products, Inc. Clad Casement Studio (Transom) - Crank-Out & Push-Out in 2026?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do you cross-check NFRC TVW and product line TVW-A-160 on delivery?

Confirm both the paper NFRC label and permanent corner glass etch match line TVW-A-160 and NFRC ID TVW before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Lincoln Wood Products, Inc. Clad Casement Studio (Transom) - Crank-Out & Push-Out come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros