Window · Wood Frame NFRC PEL · Product Line PEL-N-11 ENERGY STAR Most Efficient Eligible

Pella Corporation — Architect Clad Casement · Casement Windows

Positioning #564/1,352 in certified Window, Pella Corporation Architect Clad Casement pairs Wood frame construction with 1,129 glazing options rated between 0.11 and 0.46 SHGC across Northern, North-Central, South-Central, Southern. Across 39 certified Pella Corporation product families, its thermal resistance spans 0.19 to 0.32 U-Factor and the line includes 65 ENERGY STAR Most Efficient packages (5.8% of line).

Min U-Factor
0.19
SHGC Range
0.11-0.46
Certified Options
1,129
Category Standing
#564 of 1,352

How does Pella Corporation Architect Clad Casement compare thermally against Window peers?

Pella Corporation Architect Clad Casement achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Architect Clad CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Architect Clad Casement (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Architect Clad Casement Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Architect Clad Casement is 0.01 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.19-0.32.

Regional qualification covers Northern, North-Central, South-Central, Southern. 65 configurations meet ENERGY STAR Most Efficient criteria while 138 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 114.0 BTU/hr (-13.6% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-02-20 and cert timestamp 2024-12-17.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,129 certified glazing combinations for Architect Clad Casement (NFRC PEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 138 packages (21 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 221 packages (32 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 399 packages (22 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 999 packages (52 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Pella Corporation produce?

Compare other active Pella Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Pella Corporation Architect Clad Casement appear below.

What thermal performance numbers separate Pella Corporation Architect Clad Casement from peers?

Across 1,129 tested NFRC glazing configurations, Pella Corporation Architect Clad Casement with Wood framing and Casement Single-Vent (CSSV) style reaches a 0.19 minimum U-Factor and 0.11-0.46 SHGC band. It places #564 among 1,352 Window series—top 49.6%.

How does Pella Corporation Architect Clad Casement satisfy Version 7.0 Northern criteria?

Yes, 138 packages satisfy Northern ENERGY STAR Version 7.0 rules in Architect Clad Casement. Pairing multi-pane insulation down to 0.19 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How do you calculate winter heat conduction for Pella Corporation Architect Clad Casement?

At U 0.19, a standard 3x5 ft (15 sq ft) Architect Clad Casement opening transfers 114.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -18.0 BTU/hr difference.

What homeowner profiles are a poor match for Pella Corporation Architect Clad Casement?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Architect Clad Casement options exceeding U 0.22. Additionally, do not order Casement Single-Vent (CSSV) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Is Architect Clad Casement suitable for sunbelt cooling-dominated homes?

Yes. 999 Southern-certified options inside Pella Corporation Architect Clad Casement satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.46 SHGC on west-facing glass to avoid excess afternoon solar gain.

Which package tier in Architect Clad Casement holds Most Efficient recognition?

EPA lists 65 Most Efficient options (5.8% share) inside Pella Corporation Architect Clad Casement, out of 1,129 total Version 7.0 entries.

Can homeowners claim Form 5695 credits on Pella Corporation Architect Clad Casement in 2026?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How can homeowners confirm delivered Pella Corporation Architect Clad Casement units match permits?

Match the NFRC thermal sticker for code PEL and line PEL-N-11 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Pella Corporation Architect Clad Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros