Kolbe and Kolbe Millwork Co., Inc — Ultra Series Swing Door Transom · Picture Window
EPA ENERGY STAR Version 7.0 certifies 2,084 variants inside Kolbe and Kolbe Millwork Co., Inc Ultra Series Swing Door Transom, combining Wood frame construction with U-Factors spanning 0.19 to 0.32 and SHGC 0.09 to 0.42. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #564 of 1,352 among 1,352 Window families and posts 0.02 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median among Wood peers.
- Min U-Factor
- 0.19
- SHGC Range
- 0.09-0.42
- Certified Options
- 2,084
- Category Standing
- #564 of 1,352
How does Kolbe and Kolbe Millwork Co., Inc Ultra Series Swing Door Transom compare thermally against Window peers?
Kolbe and Kolbe Millwork Co., Inc Ultra Series Swing Door Transom achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows Kolbe and Kolbe Millwork Co., Inc Ultra Series Swing Door Transom standing at #564 of 1,352 certified Window product series, tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%. Comparing Wood profiles alone (median 0.21) shows -0.02 before selecting Low-E tiers.
Regional qualification covers Northern, North-Central, South-Central, Southern. 49 configurations meet ENERGY STAR Most Efficient criteria while 35 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 114.0 BTU/hr (-13.6% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-02-20 and cert timestamp 2024-02-29.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 2,084 certified glazing combinations for Ultra Series Swing Door Transom (NFRC KKM) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 35 packages (11 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 222 packages (28 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 787 packages (21 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 2,051 packages (42 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Sierra Pacific Windows — Alum Clad Bi-Fold OS Window | Wood | 0.19 | 0.08 | 2,117 |
| Marvin — Ultimate Double Hung Insert Transom G2 | Wood | 0.19 | 0.11 | 2,274 |
| Andersen Corporation — E-Series Hinged Patio Door Sidelight-Inswing Direct Set | Wood | 0.19 | 0.12 | 2,304 |
| JELD-WEN, inc. — Custom Wood Casement | Wood | 0.19 | 0.10 | 2,398 |
| Andersen Corporation — A-Series Frenchwood® Patio Door Transom - Direct-Set | Wood | 0.19 | 0.14 | 2,668 |
What other certified series does Kolbe and Kolbe Millwork Co., Inc produce?
Compare other active Kolbe and Kolbe Millwork Co., Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Heritage Casement Picture Sash Set
U-Factor 0.11–0.31 · 1,234 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kolbe and Kolbe Millwork Co., Inc Ultra Series Swing Door Transom appear below.
How efficient is Kolbe and Kolbe Millwork Co., Inc Ultra Series Swing Door Transom compared with peer Window models?
EPA ENERGY STAR v7.0 records 2,084 configurations for Kolbe and Kolbe Millwork Co., Inc Ultra Series Swing Door Transom covering Northern, North-Central, South-Central, Southern, dropping down to U 0.19 versus a 0.20 Window median. Only 49 options earn Most Efficient status.
How does Kolbe and Kolbe Millwork Co., Inc Ultra Series Swing Door Transom satisfy Version 7.0 Northern criteria?
Yes, 35 packages satisfy Northern ENERGY STAR Version 7.0 rules in Ultra Series Swing Door Transom. Pairing multi-pane insulation down to 0.19 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.
How does a 3x5 ft Ultra Series Swing Door Transom window perform under a 40 deg F temperature drop?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.19 U-Factor yields 114.0 BTU/hr conductive transfer (-13.6% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
Who should NOT choose Kolbe and Kolbe Millwork Co., Inc Ultra Series Swing Door Transom for a residential project?
Do not specify Ultra Series Swing Door Transom without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultra Series Swing Door Transom options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
What Southern ENERGY STAR v7.0 options exist in Ultra Series Swing Door Transom?
Warm-climate homeowners have 2,051 Southern-approved options within Ultra Series Swing Door Transom spanning SHGC down to 0.09. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
What glazing share inside Ultra Series Swing Door Transom qualifies as Most Efficient?
Not every package qualifies: 49 of 2,084 Ultra Series Swing Door Transom glazing builds earn Most Efficient recognition (2.4%), while other variants sit on the standard Version 7.0 tier.
Do 2026 Ultra Series Swing Door Transom installations qualify for IRS Section 25C tax credits?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 Kolbe and Kolbe Millwork Co., Inc upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
How can homeowners confirm delivered Kolbe and Kolbe Millwork Co., Inc Ultra Series Swing Door Transom units match permits?
Verify NFRC ID KKM and series KKM-N-253 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Kolbe and Kolbe Millwork Co., Inc Ultra Series Swing Door Transom come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)