Skip to main content
Window · Wood Frame NFRC AND · Product Line AND-N-96 ENERGY STAR Most Efficient Eligible

Andersen Corporation — A-Series Frenchwood® Patio Door Transom - Direct-Set · Transom

Andersen Corporation A-Series Frenchwood® Patio Door Transom - Direct-Set is a Transom assembly with a Wood frame that reaches a minimum U-Factor of 0.19 across 2,668 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #564 of 1,352 in Window, its thermal floor is 0.01 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.14 to 0.51.

Min U-Factor
0.19
SHGC Range
0.14-0.51
Certified Options
2,668
Category Standing
#564 of 1,352

How does Andersen Corporation A-Series Frenchwood® Patio Door Transom - Direct-Set compare thermally against Window peers?

Andersen Corporation A-Series Frenchwood® Patio Door Transom - Direct-Set achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. A-Series Frenchwood® Patio Door Transom - Direct-SetHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing A-Series Frenchwood® Patio Door Transom - Direct-Set (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

A-Series Frenchwood® Patio Door Transom - Direct-Set Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Andersen Corporation A-Series Frenchwood® Patio Door Transom - Direct-Set standing at #564 of 1,352 certified Window product series, tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%. Comparing Wood profiles alone (median 0.21) shows -0.02 before selecting Low-E tiers.

Climate coverage for Andersen Corporation A-Series Frenchwood® Patio Door Transom - Direct-Set spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 80 configurations meet ENERGY STAR Most Efficient criteria while 273 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2019-01-08 and v7.0 data certification on 2024-03-07. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.19 conducts 114.0 BTU/hr (-18.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,668 certified glazing combinations for A-Series Frenchwood® Patio Door Transom - Direct-Set (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 273 packages (22 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 673 packages (45 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 1,306 packages (31 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 2,276 packages (64 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation A-Series Frenchwood® Patio Door Transom - Direct-Set appear below.

What thermal performance numbers separate Andersen Corporation A-Series Frenchwood® Patio Door Transom - Direct-Set from peers?

Built with Wood framing in Fixed Transom (FXTR) style, Andersen Corporation A-Series Frenchwood® Patio Door Transom - Direct-Set offers 2,668 Version 7.0 configurations from U 0.19 up to 0.32, posting -0.01 against the Window median of 0.20 with 80 Most Efficient picks.

Is A-Series Frenchwood® Patio Door Transom - Direct-Set approved for Northern Zone heating climates?

Yes. 273 packages in Andersen Corporation A-Series Frenchwood® Patio Door Transom - Direct-Set clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

How much winter heat loss does A-Series Frenchwood® Patio Door Transom - Direct-Set conduct across a 15 sq ft opening?

Using NFRC AND U-Factor 0.19, a 15 sq ft Fixed Transom (FXTR) assembly conducts 114.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-18.0 BTU/hr margin).

What homeowner profiles are a poor match for Andersen Corporation A-Series Frenchwood® Patio Door Transom - Direct-Set?

Cold-climate owners needing prescriptive U <= 0.22 should pass on A-Series Frenchwood® Patio Door Transom - Direct-Set options exceeding U 0.22. Additionally, do not order Fixed Transom (FXTR) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Does A-Series Frenchwood® Patio Door Transom - Direct-Set meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 2,276 Southern-certified options inside Andersen Corporation A-Series Frenchwood® Patio Door Transom - Direct-Set satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.51 SHGC on west-facing glass to avoid excess afternoon solar gain.

What glazing share inside A-Series Frenchwood® Patio Door Transom - Direct-Set qualifies as Most Efficient?

No. Exactly 80 of 2,668 configurations (3.0%) earn ENERGY STAR Most Efficient status in A-Series Frenchwood® Patio Door Transom - Direct-Set; the remaining standard v7.0 options pass base zone limits only.

Can homeowners claim Form 5695 credits on Andersen Corporation A-Series Frenchwood® Patio Door Transom - Direct-Set in 2026?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How can homeowners confirm delivered Andersen Corporation A-Series Frenchwood® Patio Door Transom - Direct-Set units match permits?

Inspectors match the temporary NFRC sticker (U 0.19-0.32, SHGC 0.14-0.51) against permit drawings for line AND-N-96. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation A-Series Frenchwood® Patio Door Transom - Direct-Set come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros