Skip to main content
Window · Wood Frame NFRC KKM · Product Line KKM-N-285 ENERGY STAR Most Efficient Eligible

Kolbe and Kolbe Millwork Co., Inc — Ultra Push-Out Casement · Casement Windows

Kolbe and Kolbe Millwork Co., Inc engineered the Ultra Push-Out Casement Casement Windows line for Northern, North-Central, South-Central, Southern, certifying 2,500 glass-spacer combinations from 0.19 to 0.32 U-Factor and 0.09 to 0.39 SHGC. Relative to other Wood models tracked under NFRC KKM, its minimum U-Factor is 0.02 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.19
SHGC Range
0.09-0.39
Certified Options
2,500
Category Standing
#564 of 1,352

How does Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Casement compare thermally against Window peers?

Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Casement achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Ultra Push-Out CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Ultra Push-Out Casement (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Ultra Push-Out Casement Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Casement at rank #564 of 1,352 (tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.09-0.39 band.

Mapping NFRC SHGC values (0.09 to 0.39) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 868 configurations meet ENERGY STAR Most Efficient criteria while 336 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-02-20 and v7.0 data certification on 2025-08-27. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.19 conducts 114.0 BTU/hr (-18.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,500 certified glazing combinations for Ultra Push-Out Casement (NFRC KKM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 336 packages (14 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 1,442 packages (428 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 1,364 packages (428 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 2,214 packages (868 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Kolbe and Kolbe Millwork Co., Inc produce?

Compare other active Kolbe and Kolbe Millwork Co., Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Casement appear below.

What U-Factor and SHGC range does Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Casement achieve?

Built with Wood framing in Casement Single-Vent (CSSV) style, Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Casement offers 2,500 Version 7.0 configurations from U 0.19 up to 0.32, posting -0.01 against the Window median of 0.20 with 868 Most Efficient picks.

Which glazing options in Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Casement meet Northern climate limits?

Cold-climate buyers get 336 compliant Northern packages inside Ultra Push-Out Casement, reaching down to U 0.19. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

What conductive BTU/hr difference separates Ultra Push-Out Casement from the 0.22 Northern rule?

Using NFRC KKM U-Factor 0.19, a 15 sq ft Casement Single-Vent (CSSV) assembly conducts 114.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-18.0 BTU/hr margin).

When should a buyer skip Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Casement and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultra Push-Out Casement options exceeding U 0.22. Additionally, do not order Casement Single-Vent (CSSV) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Can you install Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Casement in Southern or South-Central zones?

Yes. 2,214 Southern-certified options inside Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Casement satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.39 SHGC on west-facing glass to avoid excess afternoon solar gain.

What glazing share inside Ultra Push-Out Casement qualifies as Most Efficient?

Only 868 options out of 2,500 (34.7%) meet tighter Most Efficient U-Factor and SHGC thresholds in Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Casement, usually requiring triple-pane or upgraded Low-E coatings.

Can homeowners claim Form 5695 credits on Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Casement in 2026?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Ultra Push-Out Casement retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How can homeowners confirm delivered Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Casement units match permits?

Verify NFRC ID KKM and series KKM-N-285 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros