Andersen Corporation — E-Series Hinged Patio Door Sidelight-Inswing Direct Set · Sidelite
With a minimum U-Factor of 0.19—-0.01 compared against the 0.20 Window median—Andersen Corporation E-Series Hinged Patio Door Sidelight-Inswing Direct Set spans 2,304 tested options across Northern, North-Central, South-Central, Southern up to 0.28 U-Factor. Carrying NFRC CPD code AND, the Wood assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.12 and 0.40.
- Min U-Factor
- 0.19
- SHGC Range
- 0.12-0.40
- Certified Options
- 2,304
- Category Standing
- #564 of 1,352
How does Andersen Corporation E-Series Hinged Patio Door Sidelight-Inswing Direct Set compare thermally against Window peers?
Andersen Corporation E-Series Hinged Patio Door Sidelight-Inswing Direct Set achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows Andersen Corporation E-Series Hinged Patio Door Sidelight-Inswing Direct Set standing at #564 of 1,352 certified Window product series, tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%. Comparing Wood profiles alone (median 0.21) shows -0.02 before selecting Low-E tiers.
Regional qualification covers Northern, North-Central, South-Central, Southern. 1,229 combinations qualify in the Northern Zone alongside 1,776 Southern configurations matching hot-climate SHGC <= 0.23 caps.
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 114.0 BTU/hr (-13.6% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-08 and cert timestamp 2025-04-11.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 2,304 certified glazing combinations for E-Series Hinged Patio Door Sidelight-Inswing Direct Set (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 1,229 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 1,229 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 1,776 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 1,776 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Marvin — Ultimate Double Hung Insert Transom G2 | Wood | 0.19 | 0.11 | 2,274 |
| JELD-WEN, inc. — Custom Wood Casement | Wood | 0.19 | 0.10 | 2,398 |
| Sierra Pacific Windows — Alum Clad Bi-Fold OS Window | Wood | 0.19 | 0.08 | 2,117 |
| Kolbe and Kolbe Millwork Co., Inc — Ultra Push-Out Casement | Wood | 0.19 | 0.09 | 2,500 |
| Kolbe and Kolbe Millwork Co., Inc — Ultra Push-Out Awning | Wood | 0.19 | 0.09 | 2,516 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation E-Series Hinged Patio Door Sidelight-Inswing Direct Set appear below.
How well does E-Series Hinged Patio Door Sidelight-Inswing Direct Set by Andersen Corporation insulate relative to Window benchmarks?
Across 2,304 tested NFRC glazing configurations, Andersen Corporation E-Series Hinged Patio Door Sidelight-Inswing Direct Set with Wood framing and Fixed Sidelite (FXSL) style reaches a 0.19 minimum U-Factor and 0.12-0.40 SHGC band. It places #564 among 1,352 Window series—top 49.6%.
Is E-Series Hinged Patio Door Sidelight-Inswing Direct Set approved for Northern Zone heating climates?
Andersen Corporation E-Series Hinged Patio Door Sidelight-Inswing Direct Set supplies 1,229 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.28, so inspect the NFRC order sheet before purchase.
How do you calculate winter heat conduction for Andersen Corporation E-Series Hinged Patio Door Sidelight-Inswing Direct Set?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 114.0 BTU/hr on E-Series Hinged Patio Door Sidelight-Inswing Direct Set's lowest-U package (0.19), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.28 transfer proportionally more energy.
Who should NOT choose Andersen Corporation E-Series Hinged Patio Door Sidelight-Inswing Direct Set for a residential project?
Cold-climate owners needing prescriptive U <= 0.22 should pass on E-Series Hinged Patio Door Sidelight-Inswing Direct Set options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
Is E-Series Hinged Patio Door Sidelight-Inswing Direct Set suitable for sunbelt cooling-dominated homes?
Warm-climate homeowners have 1,776 Southern-approved options within E-Series Hinged Patio Door Sidelight-Inswing Direct Set spanning SHGC down to 0.12. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
Which package tier in E-Series Hinged Patio Door Sidelight-Inswing Direct Set holds Most Efficient recognition?
All 2,304 E-Series Hinged Patio Door Sidelight-Inswing Direct Set listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.
What 2026 federal tax credit and Lead RRP rules apply to E-Series Hinged Patio Door Sidelight-Inswing Direct Set?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 Andersen Corporation upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
How do you cross-check NFRC AND and product line AND-N-185 on delivery?
Inspectors match the temporary NFRC sticker (U 0.19-0.28, SHGC 0.12-0.40) against permit drawings for line AND-N-185. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation E-Series Hinged Patio Door Sidelight-Inswing Direct Set come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)