Skip to main content
Window · Wood Frame NFRC KKM · Product Line KKM-N-286 ENERGY STAR Most Efficient Eligible

Kolbe and Kolbe Millwork Co., Inc — Ultra Push-Out Awning · Awning (Projected)

EPA ENERGY STAR Version 7.0 certifies 2,516 variants inside Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Awning, combining Wood frame construction with U-Factors spanning 0.19 to 0.32 and SHGC 0.09 to 0.39. Qualifying for Northern, North-Central, South-Central, Southern, this Awning, Projected family places #564 of 1,352 among 1,352 Window families and posts 0.02 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median among Wood peers.

Min U-Factor
0.19
SHGC Range
0.09-0.39
Certified Options
2,516
Category Standing
#564 of 1,352

How does Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Awning compare thermally against Window peers?

Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Awning achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Ultra Push-Out AwningHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Ultra Push-Out Awning (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Ultra Push-Out Awning Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Awning at rank #564 of 1,352 (tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.09-0.39 band.

Climate coverage for Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Awning spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 1,036 configurations meet ENERGY STAR Most Efficient criteria while 392 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2025-08-27 and FENSTAR license 2018-02-20 inside EPA Version 7.0 tables. Heat transfer computes to 114.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,516 certified glazing combinations for Ultra Push-Out Awning (NFRC KKM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 392 packages (12 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 1,448 packages (424 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 1,348 packages (424 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 2,230 packages (1,036 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Kolbe and Kolbe Millwork Co., Inc produce?

Compare other active Kolbe and Kolbe Millwork Co., Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Awning appear below.

Where does Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Awning stand thermally among ENERGY STAR Window lines?

Built with Wood framing in Projected Awning (PRAW) style, Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Awning offers 2,516 Version 7.0 configurations from U 0.19 up to 0.32, posting -0.01 against the Window median of 0.20 with 1,036 Most Efficient picks.

Which glazing options in Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Awning meet Northern climate limits?

Prescriptive Northern compliance covers 392 Ultra Push-Out Awning packages (U floor 0.19, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

How do you calculate winter heat conduction for Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Awning?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 114.0 BTU/hr on Ultra Push-Out Awning's lowest-U package (0.19), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

Who should NOT choose Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Awning for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultra Push-Out Awning options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Can you install Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Awning in Southern or South-Central zones?

Yes, Ultra Push-Out Awning holds 2,230 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.09 SHGC in cooling climates.

Does Ultra Push-Out Awning carry EPA Most Efficient certification across its lineup?

Within Ultra Push-Out Awning, 41.2% (1,036 of 2,516) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

Do 2026 Ultra Push-Out Awning installations qualify for IRS Section 25C tax credits?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Ultra Push-Out Awning retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

What permanent glass etch marks verify Ultra Push-Out Awning after sticker removal?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code KKM and product line KKM-N-286, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Awning come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)