Window · Wood Frame NFRC TVW · Product Line TVW-A-158 ENERGY STAR Most Efficient Eligible

Lincoln Wood Products, Inc. — Clad Casement - Crank-Out & Push-Out · Casement Windows

With a minimum U-Factor of 0.20—At median compared against the 0.20 Window median—Lincoln Wood Products, Inc. Clad Casement - Crank-Out & Push-Out spans 217 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code TVW, the Wood assembly includes 25 ENERGY STAR Most Efficient packages (11.5% of line) and offers SHGC packages between 0.15 and 0.26.

Min U-Factor
0.20
SHGC Range
0.15-0.26
Certified Options
217
Category Standing
#671 of 1,352

How does Lincoln Wood Products, Inc. Clad Casement - Crank-Out & Push-Out compare thermally against Window peers?

Lincoln Wood Products, Inc. Clad Casement - Crank-Out & Push-Out achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Clad Casement - Crank-Out & Push-OutHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Clad Casement - Crank-Out & Push-Out (U 0.20).249<=0.153140.16-0.182670.19-0.21This model: U 0.203430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Clad Casement - Crank-Out & Push-Out Cohort StandingMin U-Factor 0.20 stands at rank #671 of 1,352, outperforming 45.2% of peers.Min U-Factor 0.20Rank #671 of 1,352 (45.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Clad Casement - Crank-Out & Push-Out spans 217 NFRC test records (TVW), ranking #671 of 1,352 Window families (tied with 70 others at 0.20, more insulating than 45.2% of Window lines). Its 0.20 thermal floor compares at -0.01 against the Wood median (0.21).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 25 configurations meet ENERGY STAR Most Efficient criteria while 20 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-02-29 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 120.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 217 certified glazing combinations for Clad Casement - Crank-Out & Push-Out (NFRC TVW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 20 packages (3 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 56 packages (10 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 82 packages (8 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 201 packages (23 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Lincoln Wood Products, Inc. produce?

Compare other active Lincoln Wood Products, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Lincoln Wood Products, Inc. Clad Casement - Crank-Out & Push-Out appear below.

What U-Factor and SHGC range does Lincoln Wood Products, Inc. Clad Casement - Crank-Out & Push-Out achieve?

Built with Wood framing in Casement Single-Vent (CSSV) style, Lincoln Wood Products, Inc. Clad Casement - Crank-Out & Push-Out offers 217 Version 7.0 configurations from U 0.20 up to 0.32, posting At median against the Window median of 0.20 with 25 Most Efficient picks.

How does Lincoln Wood Products, Inc. Clad Casement - Crank-Out & Push-Out satisfy Version 7.0 Northern criteria?

Yes. 20 packages in Lincoln Wood Products, Inc. Clad Casement - Crank-Out & Push-Out clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

How do you calculate winter heat conduction for Lincoln Wood Products, Inc. Clad Casement - Crank-Out & Push-Out?

Using NFRC TVW U-Factor 0.20, a 15 sq ft Casement Single-Vent (CSSV) assembly conducts 120.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-12.0 BTU/hr margin).

Who should NOT choose Lincoln Wood Products, Inc. Clad Casement - Crank-Out & Push-Out for a residential project?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Clad Casement - Crank-Out & Push-Out options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

What Southern ENERGY STAR v7.0 options exist in Clad Casement - Crank-Out & Push-Out?

Exactly 201 Clad Casement - Crank-Out & Push-Out options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.15 rather than higher 0.26 glass.

How many Lincoln Wood Products, Inc. Clad Casement - Crank-Out & Push-Out variants earn ENERGY STAR Most Efficient?

Only 25 options out of 217 (11.5%) meet tighter Most Efficient U-Factor and SHGC thresholds in Lincoln Wood Products, Inc. Clad Casement - Crank-Out & Push-Out, usually requiring triple-pane or upgraded Low-E coatings.

How do the 25C sunset and pre-1978 Lead RRP rules affect Clad Casement - Crank-Out & Push-Out?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

What permanent glass etch marks verify Clad Casement - Crank-Out & Push-Out after sticker removal?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code TVW and product line TVW-A-158, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Lincoln Wood Products, Inc. Clad Casement - Crank-Out & Push-Out come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros