Window · Wood Frame NFRC KKM · Product Line KKM-N-272 ENERGY STAR Most Efficient Eligible

Kolbe and Kolbe Millwork Co., Inc — Ultra Casement · Casement Windows

Kolbe and Kolbe Millwork Co., Inc engineered the Ultra Casement Casement Windows line for Northern, North-Central, South-Central, Southern, certifying 893 glass-spacer combinations from 0.20 to 0.32 U-Factor and 0.09 to 0.41 SHGC. Relative to other Wood models tracked under NFRC KKM, its minimum U-Factor is 0.01 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.20
SHGC Range
0.09-0.41
Certified Options
893
Category Standing
#671 of 1,352

How does Kolbe and Kolbe Millwork Co., Inc Ultra Casement compare thermally against Window peers?

Kolbe and Kolbe Millwork Co., Inc Ultra Casement achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Ultra CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Ultra Casement (U 0.20).249<=0.153140.16-0.182670.19-0.21This model: U 0.203430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Ultra Casement Cohort StandingMin U-Factor 0.20 stands at rank #671 of 1,352, outperforming 45.2% of peers.Min U-Factor 0.20Rank #671 of 1,352 (45.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 57 certified Kolbe and Kolbe Millwork Co., Inc series, this Casement Windows offers a 0.12 U-Factor adjustment span between 0.32 entry options and 0.20 top-performing glazing. Category standing is #671/1,352 (tied with 70 others at 0.20, more insulating than 45.2% of Window lines).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 448 configurations meet ENERGY STAR Most Efficient criteria while 230 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.20 U-Factor yields 120.0 BTU/hr transfer (-12.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-02-20 licensing and 2024-03-18 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 893 certified glazing combinations for Ultra Casement (NFRC KKM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 230 packages (16 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 587 packages (212 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 528 packages (212 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 777 packages (448 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Kolbe and Kolbe Millwork Co., Inc produce?

Compare other active Kolbe and Kolbe Millwork Co., Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kolbe and Kolbe Millwork Co., Inc Ultra Casement appear below.

What thermal performance numbers separate Kolbe and Kolbe Millwork Co., Inc Ultra Casement from peers?

Built with Wood framing in Casement Single-Vent (CSSV) style, Kolbe and Kolbe Millwork Co., Inc Ultra Casement offers 893 Version 7.0 configurations from U 0.20 up to 0.32, posting At median against the Window median of 0.20 with 448 Most Efficient picks.

Does Kolbe and Kolbe Millwork Co., Inc Ultra Casement qualify for the ENERGY STAR Northern Zone?

Yes. 230 packages in Kolbe and Kolbe Millwork Co., Inc Ultra Casement clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

What conductive BTU/hr difference separates Ultra Casement from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.20 U-Factor yields 120.0 BTU/hr conductive transfer (-9.1% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

When should a buyer skip Kolbe and Kolbe Millwork Co., Inc Ultra Casement and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultra Casement options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Does Ultra Casement meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 777 Southern-certified options inside Kolbe and Kolbe Millwork Co., Inc Ultra Casement satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.41 SHGC on west-facing glass to avoid excess afternoon solar gain.

What glazing share inside Ultra Casement qualifies as Most Efficient?

Not every package qualifies: 448 of 893 Ultra Casement glazing builds earn Most Efficient recognition (50.2%), while other variants sit on the standard Version 7.0 tier.

What 2026 federal tax credit and Lead RRP rules apply to Ultra Casement?

Any Ultra Casement purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do you cross-check NFRC KKM and product line KKM-N-272 on delivery?

Confirm both the paper NFRC label and permanent corner glass etch match line KKM-N-272 and NFRC ID KKM before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kolbe and Kolbe Millwork Co., Inc Ultra Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)