Skip to main content
Window · Wood Frame NFRC KKM · Product Line KKM-N-5 ENERGY STAR Most Efficient Eligible

Kolbe and Kolbe Millwork Co., Inc — Heritage Traditional Double Hung · Double Hung

Across 57 Kolbe and Kolbe Millwork Co., Inc certified families, Heritage Traditional Double Hung supplies 196 Double Hung configurations starting at 0.20 U-Factor and 0.10 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.43 SHGC. Its thermal floor ranks #671 of 1,352 category entries—matches the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.20
SHGC Range
0.10-0.43
Certified Options
196
Category Standing
#671 of 1,352

How does Kolbe and Kolbe Millwork Co., Inc Heritage Traditional Double Hung compare thermally against Window peers?

Kolbe and Kolbe Millwork Co., Inc Heritage Traditional Double Hung achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Heritage Traditional Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Heritage Traditional Double Hung (U 0.20).249<=0.153140.16-0.182670.19-0.21This model: U 0.203430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Heritage Traditional Double Hung Cohort StandingMin U-Factor 0.20 stands at rank #671 of 1,352, outperforming 45.2% of peers.Min U-Factor 0.20Rank #671 of 1,352 (45.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Wood cohort (0.21 median U-Factor), Heritage Traditional Double Hung reaches 0.20 on its lowest-conductivity package — #169 of 408 in Wood, tied with 21 others at 0.20, more insulating than 53.4% of Wood lines, top 46.6% (-0.01 vs Wood peers). Pairing NFRC ID KKM across multi-pane fills shifts U-Factor from 0.32 down toward 0.20.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 24 configurations meet ENERGY STAR Most Efficient criteria while 16 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.20 U-Factor yields 120.0 BTU/hr transfer (-12.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-02-20 licensing and 2026-08-27 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 196 certified glazing combinations for Heritage Traditional Double Hung (NFRC KKM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 16 packages (6 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 28 packages (24 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 61 packages (22 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 188 packages (22 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Kolbe and Kolbe Millwork Co., Inc produce?

Compare other active Kolbe and Kolbe Millwork Co., Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kolbe and Kolbe Millwork Co., Inc Heritage Traditional Double Hung appear below.

How efficient is Kolbe and Kolbe Millwork Co., Inc Heritage Traditional Double Hung compared with peer Window models?

EPA ENERGY STAR v7.0 records 196 configurations for Kolbe and Kolbe Millwork Co., Inc Heritage Traditional Double Hung covering Northern, North-Central, South-Central, Southern, dropping down to U 0.20 versus a 0.20 Window median. Only 24 options earn Most Efficient status.

Can homeowners install Heritage Traditional Double Hung in cold Northern ENERGY STAR counties?

Yes. 16 packages in Kolbe and Kolbe Millwork Co., Inc Heritage Traditional Double Hung clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

What BTU/hr heat transfer results from Heritage Traditional Double Hung's 0.20 minimum U-Factor?

Using NFRC KKM U-Factor 0.20, a 15 sq ft Double-Hung (VSDH) assembly conducts 120.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-12.0 BTU/hr margin).

Who should NOT choose Kolbe and Kolbe Millwork Co., Inc Heritage Traditional Double Hung for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Heritage Traditional Double Hung options exceeding U 0.22. Additionally, do not order Double-Hung (VSDH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Is Heritage Traditional Double Hung suitable for sunbelt cooling-dominated homes?

Across Northern, North-Central, South-Central, Southern, 188 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Kolbe and Kolbe Millwork Co., Inc Heritage Traditional Double Hung, while total line SHGC reaches 0.43 in colder packages.

How many Kolbe and Kolbe Millwork Co., Inc Heritage Traditional Double Hung variants earn ENERGY STAR Most Efficient?

No. Exactly 24 of 196 configurations (12.2%) earn ENERGY STAR Most Efficient status in Heritage Traditional Double Hung; the remaining standard v7.0 options pass base zone limits only.

What 2026 federal tax credit and Lead RRP rules apply to Heritage Traditional Double Hung?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Heritage Traditional Double Hung retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How can homeowners confirm delivered Kolbe and Kolbe Millwork Co., Inc Heritage Traditional Double Hung units match permits?

Match the NFRC thermal sticker for code KKM and line KKM-N-5 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kolbe and Kolbe Millwork Co., Inc Heritage Traditional Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)