Window · Wood Frame NFRC KKM · Product Line KKM-N-288 ENERGY STAR Most Efficient Eligible

Kolbe and Kolbe Millwork Co., Inc — Ultra Inswing Casement · Casement Windows

Across 57 Kolbe and Kolbe Millwork Co., Inc certified families, Ultra Inswing Casement supplies 712 Casement Windows configurations starting at 0.20 U-Factor and 0.08 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.34 SHGC. Its thermal floor ranks #671 of 1,352 category entries—matches the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.20
SHGC Range
0.08-0.34
Certified Options
712
Category Standing
#671 of 1,352

How does Kolbe and Kolbe Millwork Co., Inc Ultra Inswing Casement compare thermally against Window peers?

Kolbe and Kolbe Millwork Co., Inc Ultra Inswing Casement achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Ultra Inswing CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Ultra Inswing Casement (U 0.20).249<=0.153140.16-0.182670.19-0.21This model: U 0.203430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Ultra Inswing Casement Cohort StandingMin U-Factor 0.20 stands at rank #671 of 1,352, outperforming 45.2% of peers.Min U-Factor 0.20Rank #671 of 1,352 (45.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Kolbe and Kolbe Millwork Co., Inc Ultra Inswing Casement at rank #671 of 1,352 (tied with 70 others at 0.20, more insulating than 45.2% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.08-0.34 band.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 320 configurations meet ENERGY STAR Most Efficient criteria while 98 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 120.0 BTU/hr (-9.1% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-02-20 and cert timestamp 2026-07-23.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 712 certified glazing combinations for Ultra Inswing Casement (NFRC KKM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 98 packages (0 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 424 packages (4 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 392 packages (4 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 632 packages (320 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Kolbe and Kolbe Millwork Co., Inc produce?

Compare other active Kolbe and Kolbe Millwork Co., Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kolbe and Kolbe Millwork Co., Inc Ultra Inswing Casement appear below.

What U-Factor and SHGC range does Kolbe and Kolbe Millwork Co., Inc Ultra Inswing Casement achieve?

EPA ENERGY STAR v7.0 records 712 configurations for Kolbe and Kolbe Millwork Co., Inc Ultra Inswing Casement covering Northern, North-Central, South-Central, Southern, dropping down to U 0.20 versus a 0.20 Window median. Only 320 options earn Most Efficient status.

Which glazing options in Kolbe and Kolbe Millwork Co., Inc Ultra Inswing Casement meet Northern climate limits?

Prescriptive Northern compliance covers 98 Ultra Inswing Casement packages (U floor 0.20, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

How much winter heat loss does Ultra Inswing Casement conduct across a 15 sq ft opening?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Ultra Inswing Casement at U 0.20 conducts 120.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Which situations make Ultra Inswing Casement the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultra Inswing Casement options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Is Ultra Inswing Casement suitable for sunbelt cooling-dominated homes?

Warm-climate homeowners have 632 Southern-approved options within Ultra Inswing Casement spanning SHGC down to 0.08. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Which package tier in Ultra Inswing Casement holds Most Efficient recognition?

Not every package qualifies: 320 of 712 Ultra Inswing Casement glazing builds earn Most Efficient recognition (44.9%), while other variants sit on the standard Version 7.0 tier.

Can homeowners claim Form 5695 credits on Kolbe and Kolbe Millwork Co., Inc Ultra Inswing Casement in 2026?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

What permanent glass etch marks verify Ultra Inswing Casement after sticker removal?

Verify NFRC ID KKM and series KKM-N-288 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kolbe and Kolbe Millwork Co., Inc Ultra Inswing Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)