Skip to main content
Window · Wood Frame NFRC TVW · Product Line TVW-A-159 ENERGY STAR Most Efficient Eligible

Lincoln Wood Products, Inc. — Clad Awning - Push-Out & Crank-Out · Awning (Projected)

Across 18 Lincoln Wood Products, Inc. certified families, Clad Awning - Push-Out & Crank-Out supplies 204 Awning, Projected configurations starting at 0.21 U-Factor and 0.14 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.26 SHGC. Its thermal floor ranks #742 of 1,352 category entries—0.01 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.21
SHGC Range
0.14-0.26
Certified Options
204
Category Standing
#742 of 1,352

How does Lincoln Wood Products, Inc. Clad Awning - Push-Out & Crank-Out compare thermally against Window peers?

Lincoln Wood Products, Inc. Clad Awning - Push-Out & Crank-Out achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Clad Awning - Push-Out & Crank-OutHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Clad Awning - Push-Out & Crank-Out (U 0.21).249<=0.153140.16-0.182670.19-0.21This model: U 0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Clad Awning - Push-Out & Crank-Out Cohort StandingMin U-Factor 0.21 stands at rank #742 of 1,352, outperforming 38.6% of peers.Min U-Factor 0.21Rank #742 of 1,352 (38.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 18 certified Lincoln Wood Products, Inc. series, this Awning, Projected offers a 0.11 U-Factor adjustment span between 0.32 entry options and 0.21 top-performing glazing. Category standing is #742/1,352 (tied with 88 others at 0.21, more insulating than 38.6% of Window lines).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 18 configurations meet ENERGY STAR Most Efficient criteria while 12 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-02-29 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 126.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 204 certified glazing combinations for Clad Awning - Push-Out & Crank-Out (NFRC TVW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 12 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 56 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 85 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 200 packages (18 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Lincoln Wood Products, Inc. produce?

Compare other active Lincoln Wood Products, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Lincoln Wood Products, Inc. Clad Awning - Push-Out & Crank-Out appear below.

How well does Clad Awning - Push-Out & Crank-Out by Lincoln Wood Products, Inc. insulate relative to Window benchmarks?

Testing puts Lincoln Wood Products, Inc. Clad Awning - Push-Out & Crank-Out at rank #742 of 1,352 Window entries with U 0.21 to 0.32 across 204 configurations. Solar heat gain ranges between 0.14 and 0.26 across Northern, North-Central, South-Central, Southern.

Is Clad Awning - Push-Out & Crank-Out approved for Northern Zone heating climates?

Lincoln Wood Products, Inc. Clad Awning - Push-Out & Crank-Out supplies 12 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

How do you calculate winter heat conduction for Lincoln Wood Products, Inc. Clad Awning - Push-Out & Crank-Out?

At U 0.21, a standard 3x5 ft (15 sq ft) Clad Awning - Push-Out & Crank-Out opening transfers 126.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -6.0 BTU/hr difference.

Which situations make Clad Awning - Push-Out & Crank-Out the wrong window or door choice?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Clad Awning - Push-Out & Crank-Out options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

Is Clad Awning - Push-Out & Crank-Out suitable for sunbelt cooling-dominated homes?

Warm-climate homeowners have 200 Southern-approved options within Clad Awning - Push-Out & Crank-Out spanning SHGC down to 0.14. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Does Clad Awning - Push-Out & Crank-Out carry EPA Most Efficient certification across its lineup?

Only 18 options out of 204 (8.8%) meet tighter Most Efficient U-Factor and SHGC thresholds in Lincoln Wood Products, Inc. Clad Awning - Push-Out & Crank-Out, usually requiring triple-pane or upgraded Low-E coatings.

Can homeowners claim Form 5695 credits on Lincoln Wood Products, Inc. Clad Awning - Push-Out & Crank-Out in 2026?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Clad Awning - Push-Out & Crank-Out retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How do you cross-check NFRC TVW and product line TVW-A-159 on delivery?

Match the NFRC thermal sticker for code TVW and line TVW-A-159 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Lincoln Wood Products, Inc. Clad Awning - Push-Out & Crank-Out come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros