Skip to main content
Window · Wood Frame NFRC WEA · Product Line WEA-N-323 ENERGY STAR Most Efficient Eligible

Weather Shield Mfg., Inc. — 8123 Double Hung Picture · Picture Window

Positioning #742/1,352 in certified Window, Weather Shield Mfg., Inc. 8123 Double Hung Picture pairs Wood frame construction with 607 glazing options rated between 0.12 and 0.50 SHGC across Northern, North-Central, South-Central, Southern. Across 30 certified Weather Shield Mfg., Inc. product families, its thermal resistance spans 0.21 to 0.32 U-Factor and the line includes 11 ENERGY STAR Most Efficient packages (1.8% of line).

Min U-Factor
0.21
SHGC Range
0.12-0.50
Certified Options
607
Category Standing
#742 of 1,352

How does Weather Shield Mfg., Inc. 8123 Double Hung Picture compare thermally against Window peers?

Weather Shield Mfg., Inc. 8123 Double Hung Picture achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 8123 Double Hung PictureHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing 8123 Double Hung Picture (U 0.21).249<=0.153140.16-0.182670.19-0.21This model: U 0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

8123 Double Hung Picture Cohort StandingMin U-Factor 0.21 stands at rank #742 of 1,352, outperforming 38.6% of peers.Min U-Factor 0.21Rank #742 of 1,352 (38.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 30 certified Weather Shield Mfg., Inc. series, this Picture Window offers a 0.11 U-Factor adjustment span between 0.32 entry options and 0.21 top-performing glazing. Category standing is #742/1,352 (tied with 88 others at 0.21, more insulating than 38.6% of Window lines).

Mapping NFRC SHGC values (0.12 to 0.50) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 11 configurations meet ENERGY STAR Most Efficient criteria while 40 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.21 U-Factor yields 126.0 BTU/hr transfer (-6.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-02-20 licensing and 2024-02-27 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 607 certified glazing combinations for 8123 Double Hung Picture (NFRC WEA) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 40 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 136 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 288 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 525 packages (11 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Weather Shield Mfg., Inc. produce?

Compare other active Weather Shield Mfg., Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Weather Shield Mfg., Inc. 8123 Double Hung Picture appear below.

How efficient is Weather Shield Mfg., Inc. 8123 Double Hung Picture compared with peer Window models?

Built with Wood framing in Fixed Window (FIXD) style, Weather Shield Mfg., Inc. 8123 Double Hung Picture offers 607 Version 7.0 configurations from U 0.21 up to 0.32, posting +0.01 against the Window median of 0.20 with 11 Most Efficient picks.

Which glazing options in Weather Shield Mfg., Inc. 8123 Double Hung Picture meet Northern climate limits?

Yes. 40 packages in Weather Shield Mfg., Inc. 8123 Double Hung Picture clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

How does a 3x5 ft 8123 Double Hung Picture window perform under a 40 deg F temperature drop?

Using NFRC WEA U-Factor 0.21, a 15 sq ft Fixed Window (FIXD) assembly conducts 126.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-6.0 BTU/hr margin).

Which situations make 8123 Double Hung Picture the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 8123 Double Hung Picture options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Does 8123 Double Hung Picture meet Southern hot-climate SHGC caps (<= 0.23)?

Warm-climate homeowners have 525 Southern-approved options within 8123 Double Hung Picture spanning SHGC down to 0.12. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

What glazing share inside 8123 Double Hung Picture qualifies as Most Efficient?

Within 8123 Double Hung Picture, 1.8% (11 of 607) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

Do 2026 8123 Double Hung Picture installations qualify for IRS Section 25C tax credits?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 8123 Double Hung Picture installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How can homeowners confirm delivered Weather Shield Mfg., Inc. 8123 Double Hung Picture units match permits?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code WEA and product line WEA-N-323, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Weather Shield Mfg., Inc. 8123 Double Hung Picture come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)