Skip to main content
Window · Wood Frame NFRC WIN · Product Line WIN-N-123 ENERGY STAR Most Efficient Eligible

Windsor Windows and Doors — Pinnacle Primed Direct Set · Picture Window

Windsor Windows and Doors engineered the Pinnacle Primed Direct Set Picture Window line for Northern, North-Central, South-Central, Southern, certifying 765 glass-spacer combinations from 0.21 to 0.32 U-Factor and 0.12 to 0.53 SHGC. Relative to other Wood models tracked under NFRC WIN, its minimum U-Factor is matches the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.21
SHGC Range
0.12-0.53
Certified Options
765
Category Standing
#742 of 1,352

How does Windsor Windows and Doors Pinnacle Primed Direct Set compare thermally against Window peers?

Windsor Windows and Doors Pinnacle Primed Direct Set achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Pinnacle Primed Direct SetHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Pinnacle Primed Direct Set (U 0.21).249<=0.153140.16-0.182670.19-0.21This model: U 0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Pinnacle Primed Direct Set Cohort StandingMin U-Factor 0.21 stands at rank #742 of 1,352, outperforming 38.6% of peers.Min U-Factor 0.21Rank #742 of 1,352 (38.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Windsor Windows and Doors Pinnacle Primed Direct Set at rank #742 of 1,352 (tied with 88 others at 0.21, more insulating than 38.6% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.12-0.53 band.

Climate coverage for Windsor Windows and Doors Pinnacle Primed Direct Set spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 20 configurations meet ENERGY STAR Most Efficient criteria while 80 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2024-04-19. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.21 conducts 126.0 BTU/hr (-6.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 765 certified glazing combinations for Pinnacle Primed Direct Set (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 80 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 143 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 335 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 686 packages (20 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Windsor Windows and Doors produce?

Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Pinnacle Primed Direct Set appear below.

What thermal performance numbers separate Windsor Windows and Doors Pinnacle Primed Direct Set from peers?

Across 765 tested NFRC glazing configurations, Windsor Windows and Doors Pinnacle Primed Direct Set with Wood framing and Fixed Window (FIXD) style reaches a 0.21 minimum U-Factor and 0.12-0.53 SHGC band. It places #742 among 1,352 Window series—more insulating than 38.6%.

Does Windsor Windows and Doors Pinnacle Primed Direct Set qualify for the ENERGY STAR Northern Zone?

Prescriptive Northern compliance covers 80 Pinnacle Primed Direct Set packages (U floor 0.21, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

How much winter heat loss does Pinnacle Primed Direct Set conduct across a 15 sq ft opening?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Pinnacle Primed Direct Set at U 0.21 conducts 126.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

When should a buyer skip Windsor Windows and Doors Pinnacle Primed Direct Set and compare alternatives?

Skip Pinnacle Primed Direct Set if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Pinnacle Primed Direct Set options exceeding U 0.22.

Can you install Windsor Windows and Doors Pinnacle Primed Direct Set in Southern or South-Central zones?

Exactly 686 Pinnacle Primed Direct Set options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.12 rather than higher 0.53 glass.

Which package tier in Pinnacle Primed Direct Set holds Most Efficient recognition?

Within Pinnacle Primed Direct Set, 2.6% (20 of 765) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

How do the 25C sunset and pre-1978 Lead RRP rules affect Pinnacle Primed Direct Set?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Pinnacle Primed Direct Set retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How can homeowners confirm delivered Windsor Windows and Doors Pinnacle Primed Direct Set units match permits?

Inspectors match the temporary NFRC sticker (U 0.21-0.32, SHGC 0.12-0.53) against permit drawings for line WIN-N-123. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Pinnacle Primed Direct Set come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros