Skip to main content
Window · Wood Frame NFRC AND · Product Line AND-N-17 ENERGY STAR Most Efficient Eligible

Andersen Corporation — 400 Series Specialty Windows - Flexiframe® · Picture Window

Across 111 Andersen Corporation certified families, 400 Series Specialty Windows - Flexiframe® supplies 1,978 Picture Window configurations starting at 0.21 U-Factor and 0.15 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.48 SHGC. Its thermal floor ranks #742 of 1,352 category entries—0.01 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.21
SHGC Range
0.15-0.48
Certified Options
1,978
Category Standing
#742 of 1,352

How does Andersen Corporation 400 Series Specialty Windows - Flexiframe® compare thermally against Window peers?

Andersen Corporation 400 Series Specialty Windows - Flexiframe® achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 400 Series Specialty Windows - Flexiframe®Histogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing 400 Series Specialty Windows - Flexiframe® (U 0.21).249<=0.153140.16-0.182670.19-0.21This model: U 0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

400 Series Specialty Windows - Flexiframe® Cohort StandingMin U-Factor 0.21 stands at rank #742 of 1,352, outperforming 38.6% of peers.Min U-Factor 0.21Rank #742 of 1,352 (38.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 400 Series Specialty Windows - Flexiframe® spans 1,978 NFRC test records (AND), ranking #742 of 1,352 Window families (tied with 88 others at 0.21, more insulating than 38.6% of Window lines). Its 0.21 thermal floor compares at At median against the Wood median (0.21).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 159 configurations meet ENERGY STAR Most Efficient criteria while 372 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2019-01-08 and v7.0 data certification on 2024-03-19. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.21 conducts 126.0 BTU/hr (-6.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,978 certified glazing combinations for 400 Series Specialty Windows - Flexiframe® (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 372 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 790 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 958 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 1,528 packages (159 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 400 Series Specialty Windows - Flexiframe® appear below.

How efficient is Andersen Corporation 400 Series Specialty Windows - Flexiframe® compared with peer Window models?

Andersen Corporation 400 Series Specialty Windows - Flexiframe® spans 1,978 certified configurations with U-Factors between 0.21 and 0.32 and SHGC values from 0.15 to 0.48. Ranked #742 of 1,352 Window families, it carries 159 Most Efficient options.

Is 400 Series Specialty Windows - Flexiframe® approved for Northern Zone heating climates?

Prescriptive Northern compliance covers 372 400 Series Specialty Windows - Flexiframe® packages (U floor 0.21, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

What conductive BTU/hr difference separates 400 Series Specialty Windows - Flexiframe® from the 0.22 Northern rule?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 400 Series Specialty Windows - Flexiframe® at U 0.21 conducts 126.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

When should a buyer skip Andersen Corporation 400 Series Specialty Windows - Flexiframe® and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 400 Series Specialty Windows - Flexiframe® options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Can you install Andersen Corporation 400 Series Specialty Windows - Flexiframe® in Southern or South-Central zones?

Warm-climate homeowners have 1,528 Southern-approved options within 400 Series Specialty Windows - Flexiframe® spanning SHGC down to 0.15. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Which package tier in 400 Series Specialty Windows - Flexiframe® holds Most Efficient recognition?

EPA lists 159 Most Efficient options (8.0% share) inside Andersen Corporation 400 Series Specialty Windows - Flexiframe®, out of 1,978 total Version 7.0 entries.

What 2026 federal tax credit and Lead RRP rules apply to 400 Series Specialty Windows - Flexiframe®?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 400 Series Specialty Windows - Flexiframe® installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

Where are NFRC and IGCC identification marks located on 400 Series Specialty Windows - Flexiframe®?

Inspectors match the temporary NFRC sticker (U 0.21-0.32, SHGC 0.15-0.48) against permit drawings for line AND-N-17. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 400 Series Specialty Windows - Flexiframe® come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros