Skip to main content
Window · Wood Frame NFRC QWP · Product Line QWP-M-148 ENERGY STAR Most Efficient Eligible

Quaker Window Products — I200W Aluminum Clad Wood Casement · Casement Windows

Across 25 Quaker Window Products certified families, I200W Aluminum Clad Wood Casement supplies 2,318 Casement Windows configurations starting at 0.21 U-Factor and 0.12 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.46 SHGC. Its thermal floor ranks #742 of 1,352 category entries—0.01 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.21
SHGC Range
0.12-0.46
Certified Options
2,318
Category Standing
#742 of 1,352

How does Quaker Window Products I200W Aluminum Clad Wood Casement compare thermally against Window peers?

Quaker Window Products I200W Aluminum Clad Wood Casement achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. I200W Aluminum Clad Wood CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing I200W Aluminum Clad Wood Casement (U 0.21).249<=0.153140.16-0.182670.19-0.21This model: U 0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

I200W Aluminum Clad Wood Casement Cohort StandingMin U-Factor 0.21 stands at rank #742 of 1,352, outperforming 38.6% of peers.Min U-Factor 0.21Rank #742 of 1,352 (38.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Quaker Window Products I200W Aluminum Clad Wood Casement at rank #742 of 1,352 (tied with 88 others at 0.21, more insulating than 38.6% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.12-0.46 band.

Climate coverage for Quaker Window Products I200W Aluminum Clad Wood Casement spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 29 configurations meet ENERGY STAR Most Efficient criteria while 52 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.21 U-Factor yields 126.0 BTU/hr transfer (-6.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-02-20 licensing and 2026-05-04 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,318 certified glazing combinations for I200W Aluminum Clad Wood Casement (NFRC QWP) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 52 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 425 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 1,007 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 2,196 packages (29 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Quaker Window Products produce?

Compare other active Quaker Window Products certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Quaker Window Products I200W Aluminum Clad Wood Casement appear below.

How efficient is Quaker Window Products I200W Aluminum Clad Wood Casement compared with peer Window models?

EPA ENERGY STAR v7.0 records 2,318 configurations for Quaker Window Products I200W Aluminum Clad Wood Casement covering Northern, North-Central, South-Central, Southern, dropping down to U 0.21 versus a 0.20 Window median. Only 29 options earn Most Efficient status.

Which glazing options in Quaker Window Products I200W Aluminum Clad Wood Casement meet Northern climate limits?

Prescriptive Northern compliance covers 52 I200W Aluminum Clad Wood Casement packages (U floor 0.21, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

What BTU/hr heat transfer results from I200W Aluminum Clad Wood Casement's 0.21 minimum U-Factor?

At U 0.21, a standard 3x5 ft (15 sq ft) I200W Aluminum Clad Wood Casement opening transfers 126.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -6.0 BTU/hr difference.

What homeowner profiles are a poor match for Quaker Window Products I200W Aluminum Clad Wood Casement?

Cold-climate owners needing prescriptive U <= 0.22 should pass on I200W Aluminum Clad Wood Casement options exceeding U 0.22. Additionally, do not order Casement Single-Vent (CSSV) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Is I200W Aluminum Clad Wood Casement suitable for sunbelt cooling-dominated homes?

Warm-climate homeowners have 2,196 Southern-approved options within I200W Aluminum Clad Wood Casement spanning SHGC down to 0.12. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Are all 2,318 I200W Aluminum Clad Wood Casement configurations ENERGY STAR Most Efficient?

No. Exactly 29 of 2,318 configurations (1.3%) earn ENERGY STAR Most Efficient status in I200W Aluminum Clad Wood Casement; the remaining standard v7.0 options pass base zone limits only.

Can homeowners claim Form 5695 credits on Quaker Window Products I200W Aluminum Clad Wood Casement in 2026?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Quaker Window Products upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How can homeowners confirm delivered Quaker Window Products I200W Aluminum Clad Wood Casement units match permits?

Match the NFRC thermal sticker for code QWP and line QWP-M-148 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Quaker Window Products I200W Aluminum Clad Wood Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros