Window · Wood Frame NFRC AND · Product Line AND-N-63

Andersen Corporation — 200 Series Gliding Window · Single Slider

Positioning #1,256/1,352 in certified Window, Andersen Corporation 200 Series Gliding Window pairs Wood frame construction with 383 glazing options rated between 0.14 and 0.23 SHGC across South-Central, Southern. Across 111 certified Andersen Corporation product families, its thermal resistance spans 0.26 to 0.32 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.26
SHGC Range
0.14-0.23
Certified Options
383
Category Standing
#1,256 of 1,352

How does Andersen Corporation 200 Series Gliding Window compare thermally against Window peers?

Andersen Corporation 200 Series Gliding Window achieves a 0.26 thermal floor across Window lines, placing #1,256 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 200 Series Gliding WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing 200 Series Gliding Window (U 0.26).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.26310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

200 Series Gliding Window Cohort StandingMin U-Factor 0.26 stands at rank #1,256 of 1,352, outperforming 4.5% of peers.Min U-Factor 0.26Rank #1,256 of 1,352 (4.5% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Andersen Corporation 200 Series Gliding Window at rank #1,256 of 1,352 (tied with 35 others at 0.26, more insulating than 4.5% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.14-0.23 band.

Regional qualification covers South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.14 lowers cooling load.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.26 U-Factor yields 156.0 BTU/hr transfer (+24.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-01-08 licensing and 2024-03-21 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 383 certified glazing combinations for 200 Series Gliding Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 84 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 383 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 200 Series Gliding Window appear below.

Where does Andersen Corporation 200 Series Gliding Window stand thermally among ENERGY STAR Window lines?

Andersen Corporation 200 Series Gliding Window spans 383 certified configurations with U-Factors between 0.26 and 0.32 and SHGC values from 0.14 to 0.23. Ranked #1,256 of 1,352 Window families, it carries 0 Most Efficient options.

Does Andersen Corporation 200 Series Gliding Window qualify for the ENERGY STAR Northern Zone?

No—with 0 Northern packages and a 0.26 thermal floor, Andersen Corporation 200 Series Gliding Window targets warmer South-Central, Southern climates instead of cold Northern installations.

How does a 3x5 ft 200 Series Gliding Window window perform under a 40 deg F temperature drop?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 156.0 BTU/hr on 200 Series Gliding Window's lowest-U package (0.26), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

When should a buyer skip Andersen Corporation 200 Series Gliding Window and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 200 Series Gliding Window options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

Can you install Andersen Corporation 200 Series Gliding Window in Southern or South-Central zones?

Warm-climate homeowners have 383 Southern-approved options within 200 Series Gliding Window spanning SHGC down to 0.14. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

What glazing share inside 200 Series Gliding Window qualifies as Most Efficient?

Zero glazing builds inside 200 Series Gliding Window's 383 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

Can homeowners claim Form 5695 credits on Andersen Corporation 200 Series Gliding Window in 2026?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 200 Series Gliding Window retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How do you cross-check NFRC AND and product line AND-N-63 on delivery?

Verify NFRC ID AND and series AND-N-63 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 200 Series Gliding Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)