Skip to main content
Door · Wood Frame NFRC JEL · Product Line JEL-N-872

JELD-WEN, inc. — Siteline / W-4500 Wood Swinging Door · Swinging Entry Door (Single)

JELD-WEN, inc. engineered the Siteline / W-4500 Wood Swinging Door Swinging Entry Door, Single line for South-Central, Southern, certifying 54 glass-spacer combinations from 0.28 to 0.28 U-Factor and 0.08 to 0.13 SHGC. Relative to other Wood models tracked under NFRC JEL, its minimum U-Factor is 0.07 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.28
SHGC Range
0.08-0.13
Certified Options
54
Category Standing
#259 of 268

How does JELD-WEN, inc. Siteline / W-4500 Wood Swinging Door compare thermally against Door peers?

JELD-WEN, inc. Siteline / W-4500 Wood Swinging Door achieves a 0.28 thermal floor across Door lines, placing #259 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Siteline / W-4500 Wood Swinging DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.28-0.30 containing Siteline / W-4500 Wood Swinging Door (U 0.28).28<=0.15650.16-0.18510.19-0.21710.22-0.24430.25-0.27100.28-0.30This model: U 0.2800.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Siteline / W-4500 Wood Swinging Door Cohort StandingMin U-Factor 0.28 stands at rank #259 of 268, outperforming 2.0% of peers.Min U-Factor 0.28Rank #259 of 268 (2.0% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Siteline / W-4500 Wood Swinging Door spans 54 NFRC test records (JEL), ranking #259 of 268 Door families (tied with 9 others at 0.28, lowest-ranked of 268 Door lines). Its 0.28 thermal floor compares at +0.07 against the Wood median (0.21).

Zone eligibility across EPA boundaries reaches 2 markets (South-Central, Southern). Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.08 lowers cooling load.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 168.0 BTU/hr (+27.3% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2024-10-11.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 54 certified glazing combinations for Siteline / W-4500 Wood Swinging Door (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 54 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 54 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.28 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Siteline / W-4500 Wood Swinging Door appear below.

Where does JELD-WEN, inc. Siteline / W-4500 Wood Swinging Door stand thermally among ENERGY STAR Door lines?

Testing puts JELD-WEN, inc. Siteline / W-4500 Wood Swinging Door at rank #259 of 268 Door entries with U 0.28 to 0.28 across 54 configurations. Solar heat gain ranges between 0.08 and 0.13 across South-Central, Southern.

Can homeowners install Siteline / W-4500 Wood Swinging Door in cold Northern ENERGY STAR counties?

No. Because Siteline / W-4500 Wood Swinging Door reaches only 0.28 U-Factor with 0 Northern combinations, it is not approved for ENERGY STAR Northern counties. Specify this Wood line strictly across South-Central, Southern cooling or mixed markets.

How do you calculate winter heat conduction for JELD-WEN, inc. Siteline / W-4500 Wood Swinging Door?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 168.0 BTU/hr on Siteline / W-4500 Wood Swinging Door's lowest-U package (0.28), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.28 transfer proportionally more energy.

Who should NOT choose JELD-WEN, inc. Siteline / W-4500 Wood Swinging Door for a residential project?

Skip Siteline / W-4500 Wood Swinging Door if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Siteline / W-4500 Wood Swinging Door options exceeding U 0.22.

What Southern ENERGY STAR v7.0 options exist in Siteline / W-4500 Wood Swinging Door?

Across South-Central, Southern, 54 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside JELD-WEN, inc. Siteline / W-4500 Wood Swinging Door, while total line SHGC reaches 0.13 in colder packages.

Are all 54 Siteline / W-4500 Wood Swinging Door configurations ENERGY STAR Most Efficient?

No. Zero of the 54 configurations in JELD-WEN, inc. Siteline / W-4500 Wood Swinging Door hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

What 2026 federal tax credit and Lead RRP rules apply to Siteline / W-4500 Wood Swinging Door?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Siteline / W-4500 Wood Swinging Door retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How do building inspectors verify Siteline / W-4500 Wood Swinging Door glass specs on job sites?

Match the NFRC thermal sticker for code JEL and line JEL-N-872 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Siteline / W-4500 Wood Swinging Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)