Skip to main content
Door · Wood Frame NFRC AND · Product Line AND-N-127

Andersen Corporation — Complementary Clad Hinged Patio Doors - Inswing · Swinging Entry Door (Double)

Positioning #259/268 in certified Door, Andersen Corporation Complementary Clad Hinged Patio Doors - Inswing pairs Wood frame construction with 48 glazing options rated between 0.11 and 0.21 SHGC across South-Central, Southern. Across 111 certified Andersen Corporation product families, its thermal resistance spans 0.28 to 0.28 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.28
SHGC Range
0.11-0.21
Certified Options
48
Category Standing
#259 of 268

How does Andersen Corporation Complementary Clad Hinged Patio Doors - Inswing compare thermally against Door peers?

Andersen Corporation Complementary Clad Hinged Patio Doors - Inswing achieves a 0.28 thermal floor across Door lines, placing #259 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Complementary Clad Hinged Patio Doors - InswingHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.28-0.30 containing Complementary Clad Hinged Patio Doors - Inswing (U 0.28).28<=0.15650.16-0.18510.19-0.21710.22-0.24430.25-0.27100.28-0.30This model: U 0.2800.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Complementary Clad Hinged Patio Doors - Inswing Cohort StandingMin U-Factor 0.28 stands at rank #259 of 268, outperforming 2.0% of peers.Min U-Factor 0.28Rank #259 of 268 (2.0% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Door assemblies nationwide (median U 0.21), Complementary Clad Hinged Patio Doors - Inswing is 0.07 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.28-0.28.

Evaluating climate compliance across South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.11 lowers cooling load.

Data provenance links certification 2024-04-09 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 168.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 48 certified glazing combinations for Complementary Clad Hinged Patio Doors - Inswing (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 48 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 48 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.28 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation Complementary Clad Hinged Patio Doors - Inswing appear below.

Where does Andersen Corporation Complementary Clad Hinged Patio Doors - Inswing stand thermally among ENERGY STAR Door lines?

EPA ENERGY STAR v7.0 records 48 configurations for Andersen Corporation Complementary Clad Hinged Patio Doors - Inswing covering South-Central, Southern, dropping down to U 0.28 versus a 0.21 Door median. Only 0 options earn Most Efficient status.

Is Complementary Clad Hinged Patio Doors - Inswing approved for Northern Zone heating climates?

Andersen Corporation Complementary Clad Hinged Patio Doors - Inswing holds zero Northern Zone qualifications (min U 0.28). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.

How do you calculate winter heat conduction for Andersen Corporation Complementary Clad Hinged Patio Doors - Inswing?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Complementary Clad Hinged Patio Doors - Inswing at U 0.28 conducts 168.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What homeowner profiles are a poor match for Andersen Corporation Complementary Clad Hinged Patio Doors - Inswing?

Do not specify Complementary Clad Hinged Patio Doors - Inswing without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Complementary Clad Hinged Patio Doors - Inswing options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Can you install Andersen Corporation Complementary Clad Hinged Patio Doors - Inswing in Southern or South-Central zones?

Yes, Complementary Clad Hinged Patio Doors - Inswing holds 48 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.11 SHGC in cooling climates.

What glazing share inside Complementary Clad Hinged Patio Doors - Inswing qualifies as Most Efficient?

Zero glazing builds inside Complementary Clad Hinged Patio Doors - Inswing's 48 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

What federal compliance checks govern 2026 Complementary Clad Hinged Patio Doors - Inswing window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do you cross-check NFRC AND and product line AND-N-127 on delivery?

Confirm both the paper NFRC label and permanent corner glass etch match line AND-N-127 and NFRC ID AND before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation Complementary Clad Hinged Patio Doors - Inswing come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros