EnergyWall Window — 3020/1520 Double Hung · Double Hung
With a minimum U-Factor of 0.23—+0.03 compared against the 0.20 Window median—EnergyWall Window 3020/1520 Double Hung spans 379 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code EWW, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.19 and 0.51.
- Min U-Factor
- 0.23
- SHGC Range
- 0.19-0.51
- Certified Options
- 379
- Category Standing
- #936 of 1,352
How does EnergyWall Window 3020/1520 Double Hung compare thermally against Window peers?
EnergyWall Window 3020/1520 Double Hung achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows EnergyWall Window 3020/1520 Double Hung standing at #936 of 1,352 certified Window product series, tied with 97 others at 0.23, more insulating than 23.6% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.04 before selecting Low-E tiers.
Mapping NFRC SHGC values (0.19 to 0.51) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 142 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2024-08-01. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.23 conducts 138.0 BTU/hr (+6.0 BTU/hr vs the 0.22 ceiling).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 379 certified glazing combinations for 3020/1520 Double Hung (NFRC EWW) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 142 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 5 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 172 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 235 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Polaris Windows and Doors — 3020/1520 Double Hung | Vinyl | 0.23 | 0.19 | 379 |
| Krestmark Industries L. P. — 250 Casement | Vinyl | 0.23 | 0.14 | 380 |
| Windsor Windows and Doors — Next Dimension Signature Sliding Patio Door Transom | Vinyl | 0.23 | 0.17 | 362 |
| YKK AP America, Inc. — Precedence Picture Window | Vinyl | 0.23 | 0.19 | 441 |
| Anlin Industries — Catalina/Del Mar/Extreme Horizontal Sliding Window | Vinyl | 0.23 | 0.13 | 259 |
What other certified series does EnergyWall Window produce?
Compare other active EnergyWall Window certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
8605/3205 Casement Picture Window
U-Factor 0.13–0.29 · 3,472 certified options.
7430/3130/8630 Horizontal Slider
U-Factor 0.15–0.32 · 1,348 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to EnergyWall Window 3020/1520 Double Hung appear below.
How well does 3020/1520 Double Hung by EnergyWall Window insulate relative to Window benchmarks?
EnergyWall Window 3020/1520 Double Hung spans 379 certified configurations with U-Factors between 0.23 and 0.32 and SHGC values from 0.19 to 0.51. Ranked #936 of 1,352 Window families, it carries 0 Most Efficient options.
Does EnergyWall Window 3020/1520 Double Hung qualify for the ENERGY STAR Northern Zone?
Prescriptive Northern approval ends at U <= 0.22, above 3020/1520 Double Hung's 0.23 minimum. However, 142 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.
What conductive BTU/hr difference separates 3020/1520 Double Hung from the 0.22 Northern rule?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.23 U-Factor yields 138.0 BTU/hr conductive transfer (+4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
When should a buyer skip EnergyWall Window 3020/1520 Double Hung and compare alternatives?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 3020/1520 Double Hung options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
What Southern ENERGY STAR v7.0 options exist in 3020/1520 Double Hung?
Exactly 235 3020/1520 Double Hung options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.19 rather than higher 0.51 glass.
Does 3020/1520 Double Hung carry EPA Most Efficient certification across its lineup?
All 379 3020/1520 Double Hung listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.
What federal compliance checks govern 2026 3020/1520 Double Hung window swaps?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
Where are NFRC and IGCC identification marks located on 3020/1520 Double Hung?
Confirm both the paper NFRC label and permanent corner glass etch match line EWW-M-3 and NFRC ID EWW before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for EnergyWall Window 3020/1520 Double Hung come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)