Skip to main content
Window · Vinyl Frame NFRC HII · Product Line HII-M-34

Harvey Industries, Inc. — Slimline Fully Welded DH / SH · Double Hung

With a minimum U-Factor of 0.24—+0.04 compared against the 0.20 Window median—Harvey Industries, Inc. Slimline Fully Welded DH / SH spans 568 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code HII, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.17 and 0.50.

Min U-Factor
0.24
SHGC Range
0.17-0.50
Certified Options
568
Category Standing
#1,034 of 1,352

How does Harvey Industries, Inc. Slimline Fully Welded DH / SH compare thermally against Window peers?

Harvey Industries, Inc. Slimline Fully Welded DH / SH achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Slimline Fully Welded DH / SHHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Slimline Fully Welded DH / SH (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Slimline Fully Welded DH / SH Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Harvey Industries, Inc. Slimline Fully Welded DH / SH standing at #1,034 of 1,352 certified Window product series, tied with 139 others at 0.24, more insulating than 13.2% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.05 before selecting Low-E tiers.

Mapping NFRC SHGC values (0.17 to 0.50) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 48 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2025-01-13 and FENSTAR license 2018-10-03 inside EPA Version 7.0 tables. Heat transfer computes to 144.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 568 certified glazing combinations for Slimline Fully Welded DH / SH (NFRC HII) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 48 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 167 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 246 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 454 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Harvey Industries, Inc. produce?

Compare other active Harvey Industries, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Harvey Industries, Inc. Slimline Fully Welded DH / SH appear below.

What U-Factor and SHGC range does Harvey Industries, Inc. Slimline Fully Welded DH / SH achieve?

EPA ENERGY STAR v7.0 records 568 configurations for Harvey Industries, Inc. Slimline Fully Welded DH / SH covering Northern, North-Central, South-Central, Southern, dropping down to U 0.24 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Is Slimline Fully Welded DH / SH approved for Northern Zone heating climates?

Northern qualification on Slimline Fully Welded DH / SH relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.24. Exactly 48 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.

What BTU/hr heat transfer results from Slimline Fully Welded DH / SH's 0.24 minimum U-Factor?

Using NFRC HII U-Factor 0.24, a 15 sq ft Double-Hung (VSDH) assembly conducts 144.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+12.0 BTU/hr margin).

When should a buyer skip Harvey Industries, Inc. Slimline Fully Welded DH / SH and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Slimline Fully Welded DH / SH options exceeding U 0.22. Additionally, do not order Double-Hung (VSDH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

How many Slimline Fully Welded DH / SH glazing packages pass Southern solar-heat rules?

Exactly 454 Slimline Fully Welded DH / SH options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.17 rather than higher 0.50 glass.

Are all 568 Slimline Fully Welded DH / SH configurations ENERGY STAR Most Efficient?

No. Zero of the 568 configurations in Harvey Industries, Inc. Slimline Fully Welded DH / SH hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

Do 2026 Slimline Fully Welded DH / SH installations qualify for IRS Section 25C tax credits?

Any Slimline Fully Welded DH / SH purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

Where are NFRC and IGCC identification marks located on Slimline Fully Welded DH / SH?

Verify NFRC ID HII and series HII-M-34 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Harvey Industries, Inc. Slimline Fully Welded DH / SH come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros