Anlin Industries — Coronado/Monte Verde/Bayview/Extreme Casement · Casement Windows

Across 14 Anlin Industries certified families, Coronado/Monte Verde/Bayview/Extreme Casement supplies 518 Casement Windows configurations starting at 0.24 U-Factor and 0.10 SHGC for North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.39 SHGC. Its thermal floor ranks #1,034 of 1,352 category entries—0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.24
SHGC Range
0.10-0.39
Certified Options
518
Category Standing
#1,034 of 1,352

How does Anlin Industries Coronado/Monte Verde/Bayview/Extreme Casement compare thermally against Window peers?

Anlin Industries Coronado/Monte Verde/Bayview/Extreme Casement achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Coronado/Monte Verde/Bayview/Extreme CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Coronado/Monte Verde/Bayview/Extreme Casement (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Coronado/Monte Verde/Bayview/Extreme Casement Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), Coronado/Monte Verde/Bayview/Extreme Casement reaches 0.24 on its lowest-conductivity package — #798 of 1,009 in Vinyl, tied with 108 others at 0.24, more insulating than 10.2% of Vinyl lines (+0.05 vs Vinyl peers). Pairing NFRC ID ANL across multi-pane fills shifts U-Factor from 0.32 down toward 0.24.

Zone eligibility across EPA boundaries reaches 3 markets (North-Central, South-Central, Southern). Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.10 lowers cooling load.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.24 U-Factor yields 144.0 BTU/hr transfer (+12.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2017-12-11 licensing and 2024-02-14 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 518 certified glazing combinations for Coronado/Monte Verde/Bayview/Extreme Casement (NFRC ANL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 71 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 299 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 510 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Anlin Industries produce?

Compare other active Anlin Industries certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Anlin Industries Coronado/Monte Verde/Bayview/Extreme Casement appear below.

Where does Anlin Industries Coronado/Monte Verde/Bayview/Extreme Casement stand thermally among ENERGY STAR Window lines?

Anlin Industries Coronado/Monte Verde/Bayview/Extreme Casement spans 518 certified configurations with U-Factors between 0.24 and 0.32 and SHGC values from 0.10 to 0.39. Ranked #1,034 of 1,352 Window families, it carries 0 Most Efficient options.

How does Anlin Industries Coronado/Monte Verde/Bayview/Extreme Casement satisfy Version 7.0 Northern criteria?

Anlin Industries Coronado/Monte Verde/Bayview/Extreme Casement holds zero Northern Zone qualifications (min U 0.24). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.

How do you calculate winter heat conduction for Anlin Industries Coronado/Monte Verde/Bayview/Extreme Casement?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.24 U-Factor yields 144.0 BTU/hr conductive transfer (+9.1% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

When should a buyer skip Anlin Industries Coronado/Monte Verde/Bayview/Extreme Casement and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Coronado/Monte Verde/Bayview/Extreme Casement options exceeding U 0.22. Additionally, do not order Casement Single-Vent (CSSV) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Can you install Anlin Industries Coronado/Monte Verde/Bayview/Extreme Casement in Southern or South-Central zones?

Yes, Coronado/Monte Verde/Bayview/Extreme Casement holds 510 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.10 SHGC in cooling climates.

What glazing share inside Coronado/Monte Verde/Bayview/Extreme Casement qualifies as Most Efficient?

All 518 Coronado/Monte Verde/Bayview/Extreme Casement listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

Do 2026 Coronado/Monte Verde/Bayview/Extreme Casement installations qualify for IRS Section 25C tax credits?

Any Coronado/Monte Verde/Bayview/Extreme Casement purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do you cross-check NFRC ANL and product line ANL-A-9 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code ANL and product line ANL-A-9, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Anlin Industries Coronado/Monte Verde/Bayview/Extreme Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)