Harvey Industries, Inc. — Vinyl Tribute Deadlite · Picture Window
With a minimum U-Factor of 0.18—-0.02 compared against the 0.20 Window median—Harvey Industries, Inc. Vinyl Tribute Deadlite spans 226 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code HII, the Vinyl assembly includes 58 ENERGY STAR Most Efficient packages (25.7% of line) and offers SHGC packages between 0.19 and 0.56.
- Min U-Factor
- 0.18
- SHGC Range
- 0.19-0.56
- Certified Options
- 226
- Category Standing
- #477 of 1,352
How does Harvey Industries, Inc. Vinyl Tribute Deadlite compare thermally against Window peers?
Harvey Industries, Inc. Vinyl Tribute Deadlite achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows Harvey Industries, Inc. Vinyl Tribute Deadlite standing at #477 of 1,352 certified Window product series, tied with 86 others at 0.18, more insulating than 58.4% of Window lines, top 41.6%. Comparing Vinyl profiles alone (median 0.19) shows -0.01 before selecting Low-E tiers.
Mapping NFRC SHGC values (0.19 to 0.56) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 58 configurations meet ENERGY STAR Most Efficient criteria while 124 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 108.0 BTU/hr (-18.2% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-10-03 and cert timestamp 2026-03-13.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 226 certified glazing combinations for Vinyl Tribute Deadlite (NFRC HII) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 124 packages (38 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 117 packages (32 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 84 packages (16 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 98 packages (30 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Joyce Manufacturing Co. — VueLine Picture Window | Vinyl | 0.18 | 0.17 | 205 |
| Joyce Manufacturing Co. — VueLine Double Hung | Vinyl | 0.18 | 0.15 | 187 |
| Comfort Window Manufacturing, Inc. — GAM-011 Double Hung | Vinyl | 0.18 | 0.20 | 184 |
| Comfort Window Manufacturing, Inc. — GAM-012 Horizontal Slider | Vinyl | 0.18 | 0.20 | 184 |
| Vinyl Design Corporation — Awning | Vinyl | 0.18 | 0.15 | 276 |
What other certified series does Harvey Industries, Inc. produce?
Compare other active Harvey Industries, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Axio Tilt Turn Window
U-Factor 0.14–0.30 · 3,474 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Harvey Industries, Inc. Vinyl Tribute Deadlite appear below.
What U-Factor and SHGC range does Harvey Industries, Inc. Vinyl Tribute Deadlite achieve?
Testing puts Harvey Industries, Inc. Vinyl Tribute Deadlite at rank #477 of 1,352 Window entries with U 0.18 to 0.32 across 226 configurations. Solar heat gain ranges between 0.19 and 0.56 across Northern, North-Central, South-Central, Southern.
Does Harvey Industries, Inc. Vinyl Tribute Deadlite qualify for the ENERGY STAR Northern Zone?
Cold-climate buyers get 124 compliant Northern packages inside Vinyl Tribute Deadlite, reaching down to U 0.18. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.
What conductive BTU/hr difference separates Vinyl Tribute Deadlite from the 0.22 Northern rule?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.18 U-Factor yields 108.0 BTU/hr conductive transfer (-18.2% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
Which situations make Vinyl Tribute Deadlite the wrong window or door choice?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Vinyl Tribute Deadlite options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
What Southern ENERGY STAR v7.0 options exist in Vinyl Tribute Deadlite?
Warm-climate homeowners have 98 Southern-approved options within Vinyl Tribute Deadlite spanning SHGC down to 0.19. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
Does Vinyl Tribute Deadlite carry EPA Most Efficient certification across its lineup?
No. Exactly 58 of 226 configurations (25.7%) earn ENERGY STAR Most Efficient status in Vinyl Tribute Deadlite; the remaining standard v7.0 options pass base zone limits only.
Can homeowners claim Form 5695 credits on Harvey Industries, Inc. Vinyl Tribute Deadlite in 2026?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 Harvey Industries, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
How do building inspectors verify Vinyl Tribute Deadlite glass specs on job sites?
Confirm both the paper NFRC label and permanent corner glass etch match line HII-M-50 and NFRC ID HII before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Harvey Industries, Inc. Vinyl Tribute Deadlite come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)