Skip to main content
Window · Vinyl Frame NFRC JMC · Product Line JMC-K-801 ENERGY STAR Most Efficient Eligible

Joyce Manufacturing Co. — VueLine Double Hung · Double Hung

Positioning #477/1,352 in certified Window, Joyce Manufacturing Co. VueLine Double Hung pairs Vinyl frame construction with 187 glazing options rated between 0.15 and 0.50 SHGC across Northern, North-Central, South-Central, Southern. Across 9 certified Joyce Manufacturing Co. product families, its thermal resistance spans 0.18 to 0.30 U-Factor and the line includes 19 ENERGY STAR Most Efficient packages (10.2% of line).

Min U-Factor
0.18
SHGC Range
0.15-0.50
Certified Options
187
Category Standing
#477 of 1,352

How does Joyce Manufacturing Co. VueLine Double Hung compare thermally against Window peers?

Joyce Manufacturing Co. VueLine Double Hung achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. VueLine Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing VueLine Double Hung (U 0.18).249<=0.153140.16-0.18This model: U 0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

VueLine Double Hung Cohort StandingMin U-Factor 0.18 stands at rank #477 of 1,352, outperforming 58.4% of peers.Min U-Factor 0.18Rank #477 of 1,352 (58.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), VueLine Double Hung reaches 0.18 on its lowest-conductivity package — #354 of 1,009 in Vinyl, tied with 74 others at 0.18, more insulating than 57.6% of Vinyl lines, top 42.4% (-0.01 vs Vinyl peers). Pairing NFRC ID JMC across multi-pane fills shifts U-Factor from 0.30 down toward 0.18.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 19 configurations meet ENERGY STAR Most Efficient criteria while 36 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-08-23 and v7.0 data certification on 2025-12-12. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.18 conducts 108.0 BTU/hr (-24.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 187 certified glazing combinations for VueLine Double Hung (NFRC JMC) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 36 packages (0 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 127 packages (4 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 116 packages (4 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 134 packages (19 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Joyce Manufacturing Co. produce?

Compare other active Joyce Manufacturing Co. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Joyce Manufacturing Co. VueLine Double Hung appear below.

Where does Joyce Manufacturing Co. VueLine Double Hung stand thermally among ENERGY STAR Window lines?

Joyce Manufacturing Co. VueLine Double Hung spans 187 certified configurations with U-Factors between 0.18 and 0.30 and SHGC values from 0.15 to 0.50. Ranked #477 of 1,352 Window families, it carries 19 Most Efficient options.

Which glazing options in Joyce Manufacturing Co. VueLine Double Hung meet Northern climate limits?

Yes. 36 packages in Joyce Manufacturing Co. VueLine Double Hung clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.30.

What conductive BTU/hr difference separates VueLine Double Hung from the 0.22 Northern rule?

At U 0.18, a standard 3x5 ft (15 sq ft) VueLine Double Hung opening transfers 108.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -24.0 BTU/hr difference.

Who should NOT choose Joyce Manufacturing Co. VueLine Double Hung for a residential project?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on VueLine Double Hung options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Does VueLine Double Hung meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 134 Southern-certified options inside Joyce Manufacturing Co. VueLine Double Hung satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.50 SHGC on west-facing glass to avoid excess afternoon solar gain.

What glazing share inside VueLine Double Hung qualifies as Most Efficient?

Not every package qualifies: 19 of 187 VueLine Double Hung glazing builds earn Most Efficient recognition (10.2%), while other variants sit on the standard Version 7.0 tier.

How do the 25C sunset and pre-1978 Lead RRP rules affect VueLine Double Hung?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current VueLine Double Hung retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How can homeowners confirm delivered Joyce Manufacturing Co. VueLine Double Hung units match permits?

Match the NFRC thermal sticker for code JMC and line JMC-K-801 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Joyce Manufacturing Co. VueLine Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros